Omron E2E-X10MB1TL18-M1: Active for New Designs

E2E-X10MB1TL18-M1 Omron product image

10mm inductive sensing, 10V ~ 30V supply, threaded M18 body, and PNP-NO output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 10MM PNP M18 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new M18 sensor installation

Design it in. Omron E2E-X10MB1TL18-M1 carries Active lifecycle status across the listed signals, with no conflict, so there is no status-based reason to restrict it to sustaining designs. EU RoHS compliance is listed. The electrical choice is narrower: this is an inductive sensor with a PNP-NO, 3-Wire output, and an input expecting different logic would require a controls change.

Will the connector-terminated sensor fit the station?

Will it fit the existing station? The threaded M18 body sets the mounting style, and connector termination calls for a matching harness interface. Check the bracket and cable arrangement before releasing the BOM: a physical mismatch stops assembly even if the sensing function is right.

The 10mm reach depends on the target and mounting

The listed 10mm sensing distance isn't a guarantee for every target; the unshielded, threaded M18 body at least makes the mounting problem concrete. Place the target and bracket before treating that distance as usable clearance. The 10V ~ 30V supply range rules out a control rail outside those limits, while the listed 400Hz response frequency is a screening ceiling, not proof that a moving target will trigger at the required point.

The -40°C ~ 85°C operating temperature range bounds the ambient choice. IP67 and IP69K are listed for the sensor, but they do not establish how a particular connector installation will withstand washdown. These limits point toward industrial position detection where the target, input logic, and mounting can be checked together; they do not settle an installation from a sensing-distance figure alone.

The bracket and switching details remain open

And that leaves the installation unfinished: without a mounting drawing or connector pinout, bracket clearance and wiring can't be frozen. Target-dependent sensing curves and switching timing details are also absent; the listed reach and response frequency do not close those checks.

View the Win-Source product page for E2E-X10MB1TL18-M1.

Key Takeaways for Engineers & Buyers

  • Check the 10mm sensing distance against the actual target position.
  • Keep the control supply within the listed 10V ~ 30V range.
  • Resolve the connector interface before releasing the M18 harness.