10 mm sensing distance, M18 threaded body, 10 V to 30 V listed supply bounds.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM PNP M18 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new inductive-sensor design-in
So E2E-X10MB218-R 5M belongs on a new-design shortlist, not just a sustaining BOM. Lifecycle Status and Product Status both read Active. No conflict is listed. Its inductive sensing and PNP-NC, 3-wire output suit a controller expecting that signal arrangement, but the sensor isn't interchangeable with one wired for a different output. EU RoHS compliance is stated without a directive revision.
Cable leads, not a connector, set the receiving check
The 3-wire output sets the wiring constraint; cable leads set the receiving check. Specify cable-lead termination on the order, then confirm it before the line builds a connection around the wrong sensor. A box is the listed package, not evidence of a fitted connector.
The 10 mm reach has an M18 mounting consequence
10 mm is the listed sensing distance, not permission to place a target at that clearance without checking how the unshielded, threaded M18 body sits among nearby metal. That combination can decide whether the sensor fits the fixture at all; a drawing is needed before cutting the mounting hole.
The 30 V supply ceiling rules out a higher rail, while the listed 10 V lower bound does not establish what happens during a supply dip. A 400 Hz response-frequency ceiling gives a first check against target rate, not a guarantee that every passing target will be detected in the installed geometry. Those limits narrow the application; they do not settle the mounting or timing conditions.
The unshielded body still needs installation detail
No mounting-clearance drawing is given. That's a consequential gap for an unshielded body. The wiring diagram and output load rating are also absent; together, these gaps prevent sign-off on fixture clearance, the controller input, and cable connections. The PNP-NC label alone cannot settle those details.
View the Win-Source product page for E2E-X10MB218-R 5M.
Key Takeaways for Engineers & Buyers
- Match the PLC input to the PNP-NC, 3-wire output.
- Keep the rail below the listed 30 V supply ceiling; assess behavior at the 10 V boundary.
- Reserve M18 mounting space and obtain clearance dimensions for the unshielded body.