10mm sensing distance, M18 threaded body, and 10V to 30V supply limits for a PNP-NC inductive sensor.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM PNP M18 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status permits a new inductive-sensor design
Design it in. E2E-X10MB2L18 2M has consistent Active lifecycle signals, so its status does not confine it to sustaining designs. Active status won't fix a mismatch between its PNP-NC, 3-Wire output and the controller input. It is EU RoHS compliant.
Box packaging affects how its cable leads are handled and kitted. Account for the boxed sensor before releasing the assembly process.
The 10mm sensing limit makes target placement decisive
10mm is the listed sensing-distance ceiling, not a guaranteed trip point for every target. With an unshielded inductive sensor, the target and surrounding metal affect detection at the intended position, particularly when a fixture depends on detection at that ceiling. The headline distance alone cannot settle the geometry.
The M18 threaded cylinder gives the mount a starting point. It is not a drop-in fit for a different bore. E2E-X10MB2L18 2M belongs where that threaded mount and a cable-lead connection fit the machine.
Supply limits and response rate bound the control scheme
10V is the lower listed supply bound; 30V is the upper ceiling. A controller supply outside those limits rules out the sensor before mounting work starts. The 400Hz response-frequency ceiling is the next check for a moving target, but it doesn't specify response time. Reading that frequency as a switching waveform cannot clear a fast event.
The -40°C to 85°C operating-temperature range provides endpoints for the ambient check. IP67 and IP69K ingress ratings make the housing worth considering where washdown or water exposure matters, but neither rating establishes how the cable termination will be installed. For E2E-X10MB2L18 2M, settle the electrical input and event rate before committing to the mount.
The M18 mount still needs installation details
The installation drawing is absent, though the M18 threaded body establishes the mounting format. Pinout, response-time detail, and target-material sensing data are also absent. The harness connection and actual detection position remain unresolved.
View the Win-Source product page for E2E-X10MB2L18 2M.
Key Takeaways for Engineers & Buyers
- Check target position against the 10mm sensing-distance ceiling.
- Match the controller input to the PNP-NC, 3-Wire output.
- Compare event rate with the 400Hz response-frequency ceiling.