10V to 30V supply, 10mm sensing distance, M18 thread and -40°C to 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM PNP M18 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new build, but cable leads set the build step
So the design-in case holds for E2E-X10MB2L18 5M: all lifecycle signals say Active, with no conflict to reconcile. EU RoHS is marked compliant. Cable leads, rather than a connector, set the build step; settle their termination before releasing the assembly.
The supply bounds the rail; 400Hz bounds the response
The limits are firm. The 10V to 30V supply range bounds rail selection: 30V is the listed upper ceiling, not permission to absorb excursions above it, while 10V is the lower bound, not proof of operation below it. A rail outside those bounds rules this sensor out.
The 400Hz response-frequency rating is a ceiling for specified target-event response; it isn't a timing diagram for the controller. The PNP-NC, 3-wire output also rules out a drop-in connection to an input expecting different logic or wiring.
The 10mm reach needs room around the M18 body
Target clearance and mounting space come first. The 10mm sensing distance and M18 threaded body constrain target placement and the mounting hole before the cable is routed. Unshielded construction makes a flush-mount assumption unsafe without mounting instructions; get the clearance wrong and a target that looked reachable on paper may not be detected reliably.
The -40°C to 85°C operating-temperature span sets the stated temperature bounds. IP67 and IP69K identify the listed ingress protections, but neither settles how the cable entry should be installed. This is a candidate for a machine-side metal-target position with room for a threaded cylinder and cable leads, not a connector-wired position whose bracket must remain unchanged.
Mounting and output details still have to come from the datasheet
Mounting geometry is missing, despite the useful M18 and ingress identifiers. A mounting drawing must establish the geometry for this unshielded body, and a wiring diagram must identify the PNP-NC lead connections. The output load-current limit is absent, leaving the controller-input match open. Response timing is absent too: 400Hz alone doesn't show whether a particular target pulse will register.
View the Win-Source product page for E2E-X10MB2L18 5M.
Key Takeaways for Engineers & Buyers
- Keep the supply within the listed 10V to 30V range.
- Set target placement against the 10mm sensing distance and unshielded mounting.
- Get the output load-current limit before assigning the sensor to a controller input.