10mm sensing distance, 10V ~ 30V supply, threaded M12 body, -25°C ~ 70°C operating temperature.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR INDUCT 10MM PNP M12 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
An unshielded M12 head needs room
A shielded-sensor requirement rules this out. E2E-X10MB3D12-R 2M belongs where the mounting geometry accommodates an unshielded inductive M12 head. Its Active lifecycle signals agree, supporting new design-in; EU RoHS compliance is listed.
The 10mm reach sets the target position
10mm is the listed sensing distance. Target position comes first: that figure won't establish detection for every target or mounting arrangement. The listed 400Hz response frequency is a ceiling, not a guarantee that every passing target registers at the controller input.
The 10V ~ 30V supply range bounds the rail; 30V is the upper ceiling, not a working setpoint, and the range says nothing about how much load the output can drive.
Cable leads change the build step
Cable leads add a termination step. IP67 and IP69K still make the sensor worth considering around sprayed machinery, but those ratings don't establish the sealing of the installed cable joint.
The PNP-NC/NO, 3-Wire output requires a controller input wired for that topology, not an assumed connectorized M12 connection. Define lead termination in the build instructions before release to a running line.
The temperature range does not close the installation details
70°C is the upper end of the listed -25°C ~ 70°C operating range. It rules out an installation whose local ambient exceeds that bound, but it does not settle sensing distance at the edge of the range.
No sensing-distance detail is given for different targets, nor is there a mounting drawing for the unshielded M12 body or a cable-lead wiring diagram for the PNP-NC/NO output. Get those items from the datasheet before fixing bracket clearance and input wiring. An output-current limit is also absent, so the controller input load cannot be signed off from the PNP label alone.
View the Win-Source product page for E2E-X10MB3D12-R 2M.
Key Takeaways for Engineers & Buyers
- Check the 10mm sensing distance against the target and mounting geometry.
- Keep the supply within the listed 10V ~ 30V range.
- Define the cable-lead termination for the PNP-NC/NO, 3-Wire input.