10mm sensing distance, M18 threaded body and -40°C ~ 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM PNP M18 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
An unshielded M18 sensor needs room around its sensing face
A shielded-mounting fixture or a controller input built for a sinking output is the wrong fit for this unshielded PNP-NC/NO, 3-wire sensor. The threaded M18 body and cable leads suit a machine-mounted sensing position with room for the face and cable. The listed 10mm sensing distance is a placement limit, not a guarantee of a 10mm installed gap for every target or near surrounding metal.
Lifecycle Status and Product Status both say Active, supporting new design-in and sustaining use. The sensor is listed as EU RoHS compliant.
Will the cable-lead configuration match the running line?
Will the buyer receive the termination the line needs? E2E-X10MB3D18 5M has cable leads; put them on the purchasing drawing and check assembly routing before release. The Box package describes packaging. It doesn't establish where the cable can run in the installed fixture.
The 400Hz figure screens timing, but cannot prove pulse capture
The weak point is timing evidence: switching conditions and waveform detail are absent. The listed 400Hz response frequency can screen the target event rate, but it isn't a switching waveform or a guarantee that every passing target registers. Controller pulse capture remains open.
The supply and temperature limits leave output loading open
The 10V lower supply boundary and 30V ceiling set the rail range to check, but neither states what load the PNP output can drive. The -40°C ~ 85°C operating temperature range bounds the installation environment, with 85°C as its upper ceiling. IP67 and IP69K are listed ingress-protection ratings; they do not establish the seal of the installed cable route.
The output load rating, wiring pinout and M18 mounting drawing are absent. Get those details from the datasheet before fixing the controller input and fixture, because PNP-NC/NO, 3-wire does not identify lead assignments and an unshielded threaded body does not specify clearance to nearby metal. A wrong connection or mounting position can leave the station missing targets even when supply and ambient conditions remain inside the listed limits.
View the Win-Source product page for E2E-X10MB3D18 5M.
Key Takeaways for Engineers & Buyers
- Set fixture spacing against the 10mm sensing-distance listing; obtain target-dependent sensing details.
- Check target event timing against the listed 400Hz response frequency.
- Specify cable leads on the M18 purchasing drawing.