Omron E2E-X10MB3D18-R 2M: Active for New Designs

E2E-X10MB3D18-R 2M Omron product image

10mm sensing ceiling, 10V to 30V supply limits and an unshielded M18 body.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 10MM PNP M18 NO/NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

Active status leaves the sensing geometry to settle

And with both lifecycle signals at Active, E2E-X10MB3D18-R 2M remains a new-design candidate, not a sustaining-only choice. EU RoHS compliance is listed. Neither fact settles the fit of the unshielded M18 body.

Will the M18 body see the target where it must?

Will it detect the actual target? The listed 10mm sensing distance is a ceiling, not a promise for every target and mounting position. With an unshielded, threaded M18 body, target clearance and nearby metal can decide the fit before control wiring does, so test the actual target at its mounting position rather than relying on a drawing alone.

The 10V to 30V supply limits exclude rails outside that range but do not establish tolerance to transients. The 3-wire PNP-NC/NO output must match the machine input; it isn't a drop-in choice for a different input arrangement. The 400Hz response-frequency ceiling can rule out faster detection demands, but it does not specify switching behavior at the installed target distance.

Cable leads put the termination in your hands

The cable needs a termination. E2E-X10MB3D18-R 2M has cable leads rather than a listed connector, so define the harness connection before releasing the assembly. Set it at the BOM stage; a sensor that fits the M18 mounting hole can still stall installation.

85°C is an operating boundary, not a mounting answer

85°C is the upper end of the stated -40°C to 85°C operating range, not a reading at the installed sensor. IP67 and IP69K are listed, but the housing ratings do not settle the cable installation. The missing wiring diagram, mounting drawing and target-dependent sensing information leave the installation check open.

View the Win-Source product page for E2E-X10MB3D18-R 2M.

Key Takeaways for Engineers & Buyers

  • Test the 10mm sensing ceiling against the actual target and mounting position.
  • Match the 3-wire PNP-NC/NO output to the machine input.
  • Specify the cable-lead termination before releasing the harness.