10mm sensing distance, 10V–30V supply limits, M12 threaded body and -25°C to 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR INDUCT 10MM NPN M12 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
An active inductive sensor for new machine builds
New designs are on the table. Omron E2E-X10MC212-R 2M is listed Active throughout its lifecycle fields, with no conflicting status. Its inductive sensing and NPN-NC, 3-wire output suit a machine that needs a normally closed signal from a metal target, but it won't detect nonmetal objects or directly match a controller expecting a different output. It is listed as EU RoHS compliant.
Unshielded mounting makes the 10mm distance conditional
The unshielded body complicates mounting, even with a listed 10mm sensing distance. Nearby metal makes mounting geometry matter; 10mm is a figure for positioning the target, not a promise that every target will switch at that distance. The M12 threaded cylinder establishes the mechanical format but not the clearance an unshielded installation needs.
The listed supply range runs from 10V to 30V. Treat 30V as a ceiling, not a preferred rail; the range does not settle supply tolerance at the sensor. The -25°C to 70°C operating range sets the stated temperature boundary. A listed 400Hz response frequency helps screen out faster events, but it does not specify the response to a particular target passing at a particular distance. IP67 and IP69K are the listed ingress-protection ratings, though neither settles how the cable entry is installed on the machine.
Will the line accept cable leads instead of a connector?
Will this line accept cable leads? The termination is cable leads, the body is threaded M12, and the package is a box. Match the termination and mounting arrangement on the build record before ordering; an assumed connector would stop installation. The Active status supports both new design-in and sustaining use.
The missing mounting details still decide release
The 10mm sensing distance constrains target placement, but the unshielded mounting-clearance drawing and target-material correction information are still needed before the sensing position is fixed. A wiring diagram and output load-current limit are also absent here. Without them, the NPN-NC interface can't be checked fully against the controller input.
View the Win-Source product page for E2E-X10MC212-R 2M.
Key Takeaways for Engineers & Buyers
- Check target position against the listed 10mm sensing distance.
- Keep the supply within the listed 10V–30V limits.
- Match the NPN-NC, 3-wire output to the controller input.