Omron E2E-X10MC218-R 2M: Active for New Designs

E2E-X10MC218-R 2M Omron product image

10mm sensing distance, 10V ~ 30V supply limits, M18 body, -40°C ~ 85°C operating bounds.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 10MM NPN M18 NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

Unshielded mounting is the first design-in question

Metal nearby is the weak point for an unshielded body. Even so, E2E-X10MC218-R 2M is a reasonable new design-in candidate: its lifecycle and product-status fields both say Active, with no stated conflict. This is an inductive sensor with a threaded M18 body and cable leads, so mounting details cannot wait until installation. EU RoHS compliance is stated.

The supply and sensing limits set different boundaries

That candidacy depends on a rail within the listed 10V ~ 30V supply limits; the range doesn't settle wiring or output-load capacity. The 10mm sensing distance is a listed reach ceiling, not a promise that every target will switch at 10mm. Target geometry cannot be fixed from that number alone. The -40°C ~ 85°C operating-temperature bounds rule out placements beyond them, but do not establish behavior at each temperature. None of these figures resolves clearance around the unshielded body.

Which cable-lead configuration goes on the order?

Which output and termination should the order specify? E2E-X10MC218-R 2M has an NPN-NC, 3-wire output and cable leads. Keep the normally closed output explicit so a different configuration does not reach the line. The stated package is Box, not an electrical connector.

A 400Hz ceiling does not close the timing check

400Hz is the listed response-frequency ceiling, not a switching-time specification. Response time and hysteresis are absent, leaving fast-target timing and repeatability unresolved. The cable-lead pinout and M18 mounting drawing are also absent. Both are needed before releasing wiring and bracket dimensions.

An M18 NPN-NC sensor is wrong for a PNP input

A control input requiring PNP output or a normally open signal rules this part out: E2E-X10MC218-R 2M is listed as NPN-NC, 3-wire. It belongs on a machine where an inductive target can approach a threaded M18 sensor and the cable leads can reach the control wiring without relying on a connector that isn't specified. The nickel-plated brass body establishes the mechanical form, and the LED provides local indication. IP67 and IP69K are the stated ingress-protection ratings. They help select the installation environment, but do not settle cable routing or the metal clearance an unshielded sensor needs. Get those dimensions before fixing the bracket.

View the Win-Source product page for E2E-X10MC218-R 2M.

Key Takeaways for Engineers & Buyers

  • Check the 10V ~ 30V supply limits against the controller rail.
  • Match the NPN-NC, 3-wire output to the controller input logic.
  • Hold bracket dimensions until the M18 mounting drawing is in hand.