10mm sensing reach, 10V to 30V supply, threaded M18 body and -40°C to 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM NPN M18 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Can this Omron inductive sensor go into a new machine?
Can this sensor go into a new machine? Yes. Both lifecycle fields mark E2E-X10MC218-R 5M Active, with no conflict between them. It’s a new design-in option, not just a sustaining choice, if the machine needs an inductive sensor with NPN-NC output. EU RoHS compliance is listed. Check the controller’s expected signal behavior early; a late mismatch can mean changing the wiring as well as the sensor.
The NPN-NC output decides fit before the 10mm reach does
This is wrong for a controller input built for PNP or normally open sensing. Its NPN-NC, 3-Wire output requires matching input circuitry and expected signal behavior. The listed 10mm sensing distance is a ceiling, not a promise that any target will switch at 10mm; test the intended target in its mount, especially since unshielded construction makes nearby metal part of the sensing setup rather than just a hole-size concern.
The supply range is 10V to 30V. Treat 30V as the ceiling, not a working setpoint; a rail outside that range does not fit the listing. The listed 400Hz response frequency matters for passing targets, but it does not state switching time for a fast sequence. The -40°C to 85°C operating range screens the machine environment. Its 85°C upper boundary does not remove the need to account for heat at the mounting point.
Cable leads change the installation plan
Cable leads complicate field replacement compared with an unplugged connector. The threaded M18 body provides a fixed machine mount, and IP67 and IP69K ingress ratings are listed for the sensor. Those ratings don’t settle chemical exposure. The part is packaged as a box and terminates in cable leads, so settle the machine-side termination and routing before releasing installation hardware.
Three missing details can stop the installation
The wiring remains unproven. The listing has no wiring diagram, output-load current limit or unshielded mounting-clearance drawing. Without them, the controller connection and acceptable load remain uncertain. The missing clearance drawing also leaves the effect of nearby metal on the intended sensing reach unresolved.
View the Win-Source product page for E2E-X10MC218-R 5M.
Key Takeaways for Engineers & Buyers
- Test the 10mm reach with the intended target and mount.
- Keep the supply within 10V to 30V; treat 30V as the ceiling.
- Plan an M18 mounting point and cable-lead termination.