10 mm sensing distance, 10V to 30V supply limits and an unshielded M12 body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR INDUCT 10MM NPN M12 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
The 10 mm distance sets the target-position question
10 mm is the listed sensing distance, not a promise that every target will switch at that gap. Put the target position on the mechanical drawing before committing to E2E-X10MC312-R 5M. The supply bounds are 10V and 30V; the latter is a ceiling, not a working setpoint. Those bounds don't establish compatibility with the controller input, and the NPN-NC/NO output still has to match the input circuit.
Active status supports a new build, within the temperature limits
New design-in is justified. Omron lists E2E-X10MC312-R 5M as Active without a conflicting lifecycle signal, so there is no stated lifecycle reason to restrict it to sustaining designs. EU RoHS compliance is listed, though no revision or exemption detail is specified.
The operating-temperature bounds are -25°C and 70°C. Treat 70°C as the upper limit, not a target cabinet temperature. The IP67 and IP69K ratings make the housing worth considering where ingress protection matters, but neither rating settles how the cable termination will be protected in the installed assembly. Get that boundary wrong and the housing rating will not rescue the connection.
An unshielded M12 body needs room around the target
A crowded flush-mount layout is wrong for this unshielded M12 cylinder. The threaded body needs a position where the target and surrounding metal can be placed deliberately. It is not a drop-in choice for a bracket laid out as though adjacent metal cannot affect sensing.
400 Hz does not settle the wiring or switching detail
400 Hz is the listed response-frequency limit, not a switching-delay measurement for your target. The pinout, mounting drawing and output load-current limit are absent here; those are the datasheet items needed to close the wiring and bracket decisions.
Cable leads set the build constraint. Put the termination on the harness drawing before ordering the boxed part; the M12 threaded housing does not imply a connector.
View the Win-Source product page for E2E-X10MC312-R 5M.
Key Takeaways for Engineers & Buyers
- Check target position against the listed 10 mm sensing distance.
- Keep the sensor supply within the listed 10V to 30V bounds.
- Specify cable-lead termination on the harness drawing.