10V to 30V supply limits, 10mm sensing distance, M18 threaded body, -40°C to 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Is this M18 sensor a new-build choice?
Can E2E-X10MC318 2M go into a new machine build? Yes. The lifecycle and product-status fields both say Active, with no conflict between them. EU RoHS compliance is listed. That settles the lifecycle question, not the electrical or mechanical fit.
Cable leads are the purchasing constraint. Put that termination on the build paperwork before ordering; a harness laid out for a connector will not accept this sensor as specified.
The NPN input and threaded mount must match
But Active status won't rescue an incompatible input. The listed NPN-NC/NO, 3-wire output calls for a matching machine input, not an assumed PNP connection. The 10V to 30V figures bound the permitted supply range; they say nothing about how much load the output can drive.
The M18 threaded, unshielded body defines the mounting approach. It cannot be treated as a flush-mounted shielded sensor, so allow for an unshielded installation when laying out the target and bracket.
The 10mm reach needs a real target check
The 10mm reach sets the placement constraint. It's a listed sensing distance, not a guarantee that every target material and installation geometry will switch at 10mm, so set the bracket around the actual target rather than treating the figure as guaranteed clearance. A missed detection becomes a machine-position fault, not a minor specification discrepancy.
The listed 400Hz response frequency is a starting point for judging moving targets, but it does not specify switching delay for the machine's particular event. The -40°C to 85°C operating-temperature range establishes the stated environmental bounds; IP67 and IP69K are also listed. Those figures support consideration for exposed industrial mounting. They do not settle the electrical load or target-spacing questions.
The harness and target geometry remain open
The listing stops short. The pinout and dimensioned drawing are needed to release the harness and bracket. The target-dependent sensing-distance curve and output load-current limit are also absent, leaving the 10mm placement and NPN input load unresolved.
View the Win-Source product page for E2E-X10MC318 2M.
Key Takeaways for Engineers & Buyers
- Keep the machine supply within the 10V to 30V limits.
- Reserve an M18 mount that accommodates an unshielded sensor.
- Compare target speed with the listed 400Hz response frequency.