10mm sensing distance, 10V ~ 30V supply bounds, M18 body; mounting details remain unresolved.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new design-in
The unshielded housing complicates mounting near metal. E2E-X10MC318 5M remains a new-design candidate where that geometry fits: its lifecycle signals agree on Active, with no stated conflict. EU RoHS compliance is listed.
The 10mm reach decides more than the switching rate
10mm is the listed sensing-distance ceiling. Check it against target travel; it does not establish detection at every mounting position. The 10V and 30V figures bound the listed supply range, ruling out this sensor for a machine rail outside those bounds. Neither figure settles what happens during a rail transient.
The listed 400Hz response frequency helps screen a fast-moving target, but it does not state the delay between target movement and output change. Frequency alone cannot settle a control sequence that depends on that delay.
Can the line terminate cable leads?
Does the line have a termination step for cable leads? E2E-X10MC318 5M is listed with cable leads and box packaging, not a connector termination. Match that step to the leads before releasing the BOM line; a connector-only harness cannot use this sensor. The M18 threaded cylinder also commits the installation to that mounting form.
IP69K does not rate the finished installation
IP69K is the sensor's listed ingress-protection class, not a rating for the assembled machine or its cable routing. The listed -40°C ~ 85°C operating-temperature range sets another fit boundary: a location outside it rules the part out, while one inside it still requires attention to the rest of the installation. IP67 is also listed. Neither class resolves how the cable entry is protected after mounting.
The M18 bracket still needs a drawing
Mounting isn't signed off. The M18 threaded cylinder identifies the housing form, but no dimensional drawing is listed; bracket depth and locknut clearance remain unresolved. An installation-clearance diagram is also absent, leaving the 10mm sensing distance and unshielded construction without the mounting detail needed to judge nearby metal.
The NPN-NC/NO, 3-Wire description identifies the output arrangement but doesn't show how to wire the selected state to an input; a wiring diagram is missing. The listed 400Hz response frequency is not a response-time specification, so obtain that timing specification before committing a sequence whose detection window depends on it.
View the Win-Source product page for E2E-X10MC318 5M.
Key Takeaways for Engineers & Buyers
- Check 10mm reach against target travel before fixing the bracket.
- Match the machine rail to the listed 10V ~ 30V supply bounds.
- Set up cable-lead termination before releasing the line build.