10mm sensing distance, 10V–30V supply limits, unshielded M18 body; mounting decides the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports this unshielded M18 sensor in new designs
That still leaves new design-in on solid ground: E2E-X10MC318-M1 is marked Active throughout its lifecycle fields, with no conflicting status. EU RoHS compliance is listed. The 10mm sensing distance makes it a candidate for inductive metal-target sensing, not a settled installed switching gap; target geometry and nearby metal still matter.
Its threaded M18, unshielded body fits a machine-mounted sensing position if the bracket allows clearance from surrounding metal, but it is the wrong match for a bracket designed to seat a shielded sensor against metal. IP67 and IP69K ingress ratings support consideration for wet equipment, provided the connector seal works as installed. The listed -40°C to 85°C operating range bounds the temperature decision, not the target-distance decision.
The 10V–30V supply range does not settle switching speed
30V is the listed supply ceiling; 10V is the lower limit. Neither is a preferred setpoint, and a control supply outside that range rules out a direct hookup. The NPN-NC/NO, 3-Wire output needs a compatible control input. Voltage compatibility won't fix an input-topology mismatch.
The listed 400Hz response frequency helps screen moving-target applications, but it is not a switching waveform or a guaranteed minimum pulse width. That figure alone cannot establish whether the controller will catch a short target event.
The M18 mounting and connector details still need drawings
The output-load limit is missing, although the NPN-NC/NO, 3-Wire designation identifies the input arrangement to check. The connector pinout and unshielded mounting-clearance drawing are also absent. Obtain those details before fixing the M18 bracket and wiring: the listed sensing distance does not establish clearance from surrounding metal, and the output label does not establish what load the sensor can drive.
Connector termination makes the mating lead a build decision
The 10V–30V supply limits do not settle the mating interface. Connector termination makes a specified mating lead a build-BOM decision before releasing E2E-X10MC318-M1. Box describes its packaging, not its connector.
View the Win-Source product page for E2E-X10MC318-M1.
Key Takeaways for Engineers & Buyers
- Check the 10mm sensing distance against the target and unshielded mounting clearance.
- Keep the control supply within the listed 10V–30V limits.
- Match the NPN-NC/NO, 3-Wire output to the input and obtain the connector pinout.