10 mm sensing limit, 10V to 30V supply, unshielded M18 body, -40°C to 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new M18 installation
And that takes lifecycle uncertainty out of the decision: all lifecycle signals say Active, making E2E-X10MC318-R 2M a new-design candidate rather than a sustaining-only choice. The installation still has to accept an unshielded M18 sensor with cable leads.
EU RoHS compliance is stated. For a running line, define how those leads enter the machine wiring before releasing the assembly.
The 10 mm reach does not settle target clearance
Mounting geometry is the weak point, even with a listed 10 mm sensing distance to work from. That number is a ceiling, not a guaranteed gap to every target; using it as working clearance risks missed detections once the unshielded M18 body is installed. The 10V to 30V supply range bounds the rail choice, but neither endpoint establishes tolerance to a particular machine’s voltage excursions.
The listed 400Hz response frequency is also a ceiling. It can rule out a motion sequence that plainly demands more, but it doesn't establish detection performance for the actual target and travel path. A target can be close enough yet pass too quickly. Timing may also fit while the installed gap does not.
NPN output makes controller fit a separate decision
Wiring is a separate fit. E2E-X10MC318-R 2M is a machine-mounted sensor with an NPN-NC/NO, 3-wire output and cable leads. Match the controller input and chosen contact behavior before fixing the wiring. The LED provides a local indication during setup, not proof that the controller sees the intended state.
The -40°C to 85°C operating range sets the installation’s temperature boundary. IP67 and IP69K are listed, but neither resolves whether the unshielded threaded body can sit where the target must pass.
The 10 mm rating leaves mounting details open
The 10 mm ceiling leaves the installed gap unresolved. Target-material response data and a mounting drawing are still needed to establish it. The cable-wire assignment and output load-current limit are also absent, so the controller connection cannot be finalized.
View the Win-Source product page for E2E-X10MC318-R 2M.
Key Takeaways for Engineers & Buyers
- Set target clearance against the 10 mm sensing ceiling.
- Match the controller input to the NPN-NC/NO, 3-wire output.
- Define cable-lead termination before releasing the M18 assembly.