Supply-voltage and sensing-distance limits are unstated; Box describes packaging, not the sensor housing.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Core function | SENSOR PROX |
Active status permits consideration, not release
2M is part of the ordering code, not a stated cable length. E2E-X10MD112-T 2M is marked Active in both the lifecycle and product-status fields, so lifecycle alone does not rule out a new design-in. The industrial proximity-sensor category identifies its intended job, but does not establish machine fit. The RoHS fields also disagree.
The machine fit cannot be settled from Box packaging
Fit remains unproven. A missing sensing distance leaves target clearance unset, while the absent output type and supply-voltage range prevent selection of the controller input and approval of the control rail. No operating-temperature limit is stated, so the enclosure location cannot be cleared. Box describes packaging, not the installed body or mounting envelope.
Industrial object detection is the likely application, but that does not settle the installation. A machine builder can identify the intended sensing function here. They can't release the wiring or cut a mounting hole from these fields.
Can this sensor go on the BOM?
Can I release this sensor on a compliance-controlled BOM? The compliance field says RoHS Compliant, while the specification says RoHS Non-Compliant. A manufacturer declaration must resolve the conflict before a compliance-controlled purchase is released; put the exact ordering code on the request so the answer applies to the intended sensor.
Missing limits still block placement and wiring
The rail decision has no numeric limit to work from. Obtain the sensing distance with target conditions and the supply-voltage range; the output configuration and mounting drawing are also missing. Until those are known, target placement and wiring remain open.
View the Win-Source product page for E2E-X10MD112-T 2M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting RoHS fields before releasing a compliance-controlled BOM.
- Obtain the sensing distance before setting target clearance.
- Get the supply-voltage range and output type before assigning a controller input.