Omron E2E-X10ME1: Discontinued, for Sustaining Designs

E2E-X10ME1 Omron product image

10mm sensing, 10V ~ 40V supply and M18 threaded body; discontinued for new designs.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 40V

Does 10mm reach justify keeping this sensor?

10mm is the listed inductive sensing distance. It won't tell you where a particular target switches in its installed position; a missed target can stop an existing machine's cycle even when the nominal distance looks sufficient.

Keep the part in sustaining designs, not new ones. One lifecycle signal says EOL; the lifecycle and product status fields say Discontinued. The wording conflicts, but neither supports new design-in. EU RoHS compliance is listed.

The M18 mount and output must match the machine

Nor does reach settle the electrical fit. The listed 10V ~ 40V supply range puts 40V at the ceiling and 10V at the lower bound; the NPN-NO, 3-wire output still has to suit the controller input. The 200Hz response-frequency figure helps screen the event rate, not switching time.

The M18 threaded, unshielded body needs a machine position that accepts that mount and sensing arrangement, rather than just an opening big enough for a cylinder. IP67 is the listed ingress-protection rating; it doesn't settle how cable leads are routed or protected on the machine.

What still blocks a sensing check?

Missing installation detail is the weak point, not the listed 10mm distance. Target conditions for that distance, unshielded mounting clearances and an output wiring diagram are absent here. Without them, the installed target's registration and the controller connection remain unresolved.

Can an existing line keep using the bulk-packed sensor?

Can the next build use the same receiving and installation process? Bulk packaging and cable leads put handling and termination on the build checklist; match both to the installed process before release. For this discontinued part, secure inventory for existing production and plan migration. The lifecycle wording conflict is no reason to start a new design around it.

View the Win-Source product page for E2E-X10ME1.

Key Takeaways for Engineers & Buyers

  • Check the 10mm sensing distance against the installed target.
  • Match the NPN-NO, 3-wire output to the controller input.
  • Secure E2E-X10ME1 inventory for existing production; plan migration.