Omron E2E-X10ME2: Discontinued, for sustaining builds only

E2E-X10ME2 Omron product image

10mm inductive reach, M18 threaded body, 10V to 40V supply limits, and cable leads.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 40V

Discontinued status outweighs the 10mm reach

10mm of listed sensing distance cannot offset discontinued status. Both lifecycle fields agree: E2E-X10ME2 is out of production. Even if the reach fits, leave it out of new designs. EU RoHS compliance does not change that decision.

Unshielded sensing needs room around the M18 body

Unshielded construction limits mounting freedom, though the M18 threaded cylinder gives an existing fixture a clear first fit check. Nearby metal and the actual target can determine whether the listed 10mm reach holds. Cable leads also rule out a connector-at-sensor swap without a wiring change.

IP67 doesn't settle how the cable end is sealed in the machine. The nickel-plated brass body and LED indicator help identify the physical fit, but neither settles the sensing geometry.

The supply limits screen the rail, not its transients

10V is the lower listed supply limit; 40V is the upper ceiling. Those bounds screen the machine rail, not its transients. The -40°C to 85°C operating-temperature range provides an ambient fit check but does not account for heat at the installed sensor.

The 200Hz response-frequency listing screens the event rate, not the response time needed to judge a narrow passing target. NPN-NC, 3-wire output is another hard boundary: changing the mount will not make it compatible with a controller expecting normally open behavior.

Keep E2E-X10ME2 on the sustaining BOM only

Existing production only. Match each cable-lead sensor to the approved BOM before assembly: bulk packaging gives the line no connector-based way to identify it at installation. Secure inventory for the running line and plan migration rather than carrying this part into a new machine.

The missing wiring diagram and mechanical drawing block a full connection and mounting check; M18 and cable leads do not specify either interface in full. Without a sensing-distance curve by target material, the listed 10mm reach remains unproven for the actual target. The response-time specification is also absent, so the 200Hz listing alone cannot settle whether a narrow passing target will be detected.

View the Win-Source product page for E2E-X10ME2.

Key Takeaways for Engineers & Buyers

  • Check the M18 threaded mount against the existing fixture.
  • Compare the 10V to 40V supply limits with the machine rail and its transients.
  • Keep the NPN-NC, 3-wire input logic on the sustaining BOM.