Omron E2E-X10MF1: Discontinued, for Sustaining Designs Only

E2E-X10MF1 Omron product image

10mm sensing, M18 threaded body, 10V to 40V supply limits; discontinued.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 40V

Discontinued, but still a defined fit for an M18 station

Discontinued is the weak point. One lifecycle tag says EOL while the status fields say Discontinued; neither supports new design-in. On an existing line, though, E2E-X10MF1 has a defined fit: an unshielded, threaded M18 inductive body with cable leads and a PNP-NO, 3-Wire output.

The listed 10mm sensing distance is a starting point for target placement, not proof that the installed target will switch at that gap. The M18 mounting and PNP input must suit the machine, or a sensor change becomes mechanical rework or rewiring. It is listed as EU RoHS compliant.

What does bulk packaging change on the line?

Will bulk packaging fit the line's receiving process? Keep the cable-lead sensor matched to kitting and termination, and plan migration before the discontinued part forces a production change.

The supply rail and response limit set different boundaries

At the machine, the 10V to 40V supply limits bound the rail choice but say nothing about tolerance to disturbances on that rail. The listed 200Hz response frequency is a ceiling for judging whether the sensor can follow passing targets, not a switching-time specification. A faster event calls for timing information this figure cannot supply.

The -40°C to 85°C operating-temperature range helps screen ambient conditions, while IP67 describes the listed ingress protection. Neither settles performance beside the actual target.

The wiring and mounting details remain open

The wiring is unresolved. No pinout or mounting drawing is listed, leaving the cable connections and installed geometry open. The output-current limit and target-dependent sensing information are also absent; both matter before committing an input circuit or relying on the 10mm distance.

View the Win-Source product page for E2E-X10MF1.

Key Takeaways for Engineers & Buyers

  • Keep E2E-X10MF1 on sustaining BOMs; plan migration.
  • Check the 10mm sensing distance against the installed target.
  • Match the machine rail to the 10V to 40V supply limits.