10mm sensing distance, 100 VAC ~ 120 VAC supply bounds, unshielded M18 body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 100 VAC ~ 120 VAC |
Discontinued status limits this sensor to sustaining designs
A 10mm sensing distance doesn't change the lifecycle decision: keep E2E-X10MY1-53-US in existing production only while planning migration. One lifecycle signal says EOL; the lifecycle and product status fields say Discontinued. The labels differ. The decision does not support new design-in.
Its SCR-NO, 2-wire output makes a sensor change an electrical question, not just a mechanical one. A replacement plan must account for the receiving input as well as the mounting position.
The 10mm reach and 25Hz ceiling decide what it can detect
10mm is the listed sensing distance, not permission to place a target exactly at that gap under every mounting condition. The unshielded M18 threaded cylinder needs an installation that preserves detection, because a missed target can stop a machine even when the stated sensing distance appears to fit. The 100 VAC ~ 120 VAC listing sets supply bounds, not a suggested setpoint; a different control rail needs an electrical change.
25Hz is the listed response-frequency ceiling, not an operating point or a response-time rating. It rules out treating the sensor as an unrestricted event counter. The -40°C ~ 85°C operating-temperature range bounds the stated environment but does not settle the temperature at the installed sensor. These limits suit a fixed industrial proximity point, not a fast target on an assumed supply or mounting arrangement.
Can the running line retain the bulk, cable-lead build?
Can the running line keep this bulk, cable-lead build? For E2E-X10MY1-53-US, keep build instructions tied to its bulk packaging and cable-lead termination while migration is planned. The RoHS fields conflict: one says compliant, another non-compliant. Resolve that contradiction before a compliance-controlled build.
The SCR-NO input still needs wiring and leakage data
A wiring change made from a part description alone is the wrong use for this sensor. In an existing build, its SCR-NO, 2-wire output still needs a wiring diagram and an output leakage-current rating before it can be assessed against the receiving input. A mounting drawing and sensing-distance test conditions would establish how the stated 10mm applies to the actual target and installation. Those details are absent here; the listed limits cannot settle those decisions.
View the Win-Source product page for E2E-X10MY1-53-US.
Key Takeaways for Engineers & Buyers
- Exclude new design-in: lifecycle status is Discontinued.
- Match the control rail to the 100 VAC ~ 120 VAC supply bounds.
- Resolve the conflicting RoHS fields before a compliance-controlled build.