10 mm sensing distance, 25 Hz response, 20 VAC to 264 VAC supply, M18 threaded body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
The 10 mm reach does not settle target detection
Reach and switching speed set different limits. The listed 10 mm sensing distance must be checked against the target path; it does not establish detection at that distance for every metal or mounting arrangement. The 25 Hz response frequency must be checked against the machine cycle. Faster events risk being missed.
The 20 VAC to 264 VAC supply limits bound the circuit this sensor can enter, not the load current its SCR-NO, 2-wire output can carry. The -40°C to 85°C operating range bounds the temperature check for the sensing position; it does not settle conditions at the mounting point.
Active status supports a new E2E-X10MY1-US design-in
Active status supports new design-in. Lifecycle and product status both read Active, with no stated conflict, so there is no lifecycle reason to confine E2E-X10MY1-US to sustaining designs. The electrical interface remains a separate question: the receiving circuit must accommodate an SCR-NO, 2-wire output on the specified AC supply. EU RoHS compliance is listed, without a revision.
The unshielded M18 body needs mounting room
It's wrong for a flush metal installation without a clearance check, or for an input expecting a different output topology. The unshielded M18 threaded body belongs at an industrial machine sensing point where its position relative to nearby metal can be controlled.
Can the line handle bulk-packed cable leads?
Can the line handle bulk-packed cable-lead sensors? Put cable-lead termination on the build route rather than treating E2E-X10MY1-US as connectorized. Active status doesn't remove that assembly step; missing it can stop an otherwise suitable sensor at the wiring bench.
The SCR output still needs load and wiring details
That wiring step still needs a diagram: SCR-NO, 2-wire identifies the output type but not the conductor assignments. The load-current limit is also absent, so the 20 VAC to 264 VAC supply limits cannot establish whether the connected load stays within the sensor's output capability.
Off-state leakage needs a figure before the receiving input can be assessed for false indications. At the sensing end, the unshielded M18 body needs mounting-clearance guidance before a bracket is cut or adjacent metal is fixed near the face. Before committing the circuit and bracket, get the wiring diagram, load-current limit, leakage figure and mounting guidance from the datasheet; the 10 mm sensing-distance listing cannot answer those questions.
View the Win-Source product page for E2E-X10MY1-US.
Key Takeaways for Engineers & Buyers
- Check the target path against the listed 10 mm sensing distance.
- Keep event timing within the listed 25 Hz response frequency.
- Add cable-lead termination to the build route for bulk-packed units.