10mm sensing limit, 25Hz response ceiling and M18 threaded body for an AC input circuit
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
Fast targets can outrun this unshielded M18 sensor
Fast indexing is a poor fit. For E2E-X10MY1, the listed 25Hz response frequency is a ceiling, not a guaranteed switching rate; faster target events risk going unseen. The 10mm sensing distance is a limit, not a promise of that reach against every target. Reject layouts that need more distance and test the actual target at the intended position.
The M18 threaded cylinder and cable leads suit a machine-mounted sensing point, not a PCB. Because the sensor is unshielded, surrounding metal belongs in the mounting check. The Active lifecycle signals agree, so new design-in is defensible when that geometry and the AC interface fit. It is listed as EU RoHS compliant.
What must stay fixed on repeat orders?
Will repeat orders arrive with the same build? E2E-X10MY1 is marked Active in both lifecycle and product-status fields, with no conflict between them. Bulk packaging is the handling constraint; specify the cable-lead, M18 build so incoming sensors go to the intended assembly process. A connectorized build would change that process, but none is specified for this part.
The AC supply window does not settle input compatibility
That still leaves the AC interface. The listed supply range starts at 20 VAC and has a 264 VAC ceiling; neither boundary establishes how the SCR-NO, 2-wire output behaves with the receiving input. Don’t treat it as a dry contact by assumption.
The -40°C to 85°C operating-temperature range sets the stated environmental window, while IP67 states an ingress-protection rating. Neither closes the electrical interface question. A wet installation still needs attention at the cable termination.
The wiring and mounting details remain open
The weak point is the missing interface detail: off-state leakage and load-current limits are absent, so the receiving input cannot be settled here. The M18 threaded form gives the mechanical layout a starting point, but the wiring diagram and mounting drawing are also absent. Obtain those before fixing the wiring scheme or panel geometry.
View the Win-Source product page for E2E-X10MY1.
Key Takeaways for Engineers & Buyers
- Test the actual target within the listed 10mm sensing limit.
- Match the 20 VAC ~ 264 VAC supply window to the machine circuit.
- Allow for the unshielded M18 body in the mounting layout.