Omron E2E-X10MY2-M4: Active for New Sensor Designs

E2E-X10MY2-M4 Omron product image

10mm sensing distance, 20 VAC ~ 264 VAC supply, M18 threaded body; check SCR-NC load compatibility.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: SCR-NC, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC

Will the 10mm sensing distance work in an M18 mount?

10mm is the listed sensing distance, not a promise for every target or mount. The unshielded M18 threaded body needs room for its sensing face; test E2E-X10MY2-M4 with the intended target to establish the switch point.

Active status permits a new design-in

New design-in is reasonable. The lifecycle statuses agree on Active, with no listed conflict. EU RoHS compliance also supports specifying the sensor for a new machine or retaining it on an existing line, though neither status settles electrical fit.

Bulk packaging affects line handling. Set up the kit for a connector-terminated sensor rather than an individually packed, prewired unit.

The AC output limits where this sensor belongs

25Hz response frequency is the weak point when targets pass quickly, and no response-time measurement is listed for the intended speed. The 20 VAC ~ 264 VAC supply range fits an AC-fed circuit but rules out a DC sensor input, while the SCR-NC, 2-Wire output leaves load compatibility as a separate gate.

The -40°C ~ 85°C operating range bounds ambient conditions; it does not settle heat at the mounting point.

IP67 does not settle the connector or input circuit

IP67 is listed for the sensor, but it doesn't establish protection at the mated connection without connector mating details. The pinout and connector drawing are absent; obtain them before fixing the harness. Load-current limits and off-state leakage are also absent, leaving open whether the SCR-NC, 2-Wire output will switch the chosen input reliably.

View the Win-Source product page for E2E-X10MY2-M4.

Key Takeaways for Engineers & Buyers

  • Test 10mm switching with the actual target and unshielded M18 mount.
  • Match the 20 VAC ~ 264 VAC supply and SCR-NC, 2-Wire output to the control circuit.
  • Set up bulk handling for the connector-terminated assembly.