Omron E2E-X10Y1-US-5M: Sustaining Designs Only

E2E-X10Y1-US-5M Omron product image

20 VAC to 264 VAC supply, 10 mm sensing distance and an M30 threaded body.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIV 10MM CYL 5M
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC

The lifecycle signals rule out a new M30 design-in

So this belongs in sustaining designs, not a fresh design-in. The EOL lifecycle signal conflicts with fields marked Discontinued; neither supports calling the sensor Active. Stated EU RoHS compliance does not change that call.

Even with a matching threaded mount, the SCR-NO, 2-wire output can stop a running line if the existing input circuit expects a different sensor output.

Can the existing AC sensor line keep using it?

Can the running line keep this sensor? Yes, if its circuit and installation already use E2E-X10Y1-US-5M, but secure inventory before committing to further production and plan migration. Discontinued status can stop the line.

The sensor comes in bulk packaging with cable leads. Handle the leads during assembly; a damaged cable can defeat an otherwise sound installation.

10 mm sensing does not settle the AC circuit

10 mm is the listed sensing distance. It isn't a guarantee for every target or mounting arrangement; test the actual target in the intended shielded M30 installation. The threaded M30 body establishes the mounting format, not the clearance around the installed cable.

The 20 VAC to 264 VAC supply range defines circuit-compatibility bounds, not a preferred setpoint. The listed 25 Hz response frequency is a ceiling, not support for a faster counting task. The -25°C to 70°C operating-temperature range bounds the installation environment, not the temperature inside a heated enclosure.

A DC input is wrong, and the wiring is still open

A DC-only input won't work here, nor will a faster counting task. The fit is an existing AC SCR-NO circuit with an M30 mount. The wiring diagram, output load-current limit and mounting drawing are absent; those details are needed to settle the connection and installed clearance.

View the Win-Source product page for E2E-X10Y1-US-5M.

Key Takeaways for Engineers & Buyers

  • Secure inventory and plan migration for existing production.
  • Check the existing circuit against the 20 VAC to 264 VAC supply bounds.
  • Test detection at 10 mm in the intended M30 mounting arrangement.