Omron E2E-X10Y1-US: Active for new inductive designs

E2E-X10Y1-US Omron product image

10mm sensing distance, 25Hz response limit, M30 threaded body and 20 VAC to 264 VAC supply limits.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC

Cable leads rule out a connectorized sensor harness

A connectorized sensor harness is wrong for this cable-lead part. For metal-presence detection, the 10mm listed sensing distance and shielded inductive construction make E2E-X10Y1-US a candidate where an M30 threaded body fits. That figure doesn't establish reach against every target.

Omron marks the part Active, with no lifecycle conflict, so new design-in is reasonable if the input circuit fits. It is EU RoHS compliant. With bulk packaging, cable-lead preparation becomes an assembly decision: specify the termination process before releasing a running build.

The 25Hz limit puts fast target counts out of reach

25Hz is the listed response-frequency ceiling. It is no promise that every passing target will register at that rate. The required target rate has to stay below the limit.

The AC span helps only if the input accepts SCR-NO

The weak point is the SCR-NO, 2-Wire output: an existing input can't be assumed to recognize it just because the M30 body fits the mount. The listed 20 VAC to 264 VAC supply span helps screen the supply, with 264 VAC as its upper ceiling and 20 VAC as its lower boundary, but it does not settle input compatibility.

The -25°C to 70°C operating-temperature range screens machine locations; its 70°C top end still calls for attention to temperature at the installed sensor. The threaded cylinder provides a mounting starting point, while the cable leads require a termination decision at the machine. This AC inductive switch needs a compatible input; physical fit alone is not enough.

The missing output details hold up the input decision

And that input question remains open without a wiring diagram and output load-current limits. Off-state leakage is absent here too; it matters when deciding whether the receiving input sees the SCR-NO output as open. Target correction factors would show how the listed 10mm sensing distance applies to the actual target.

View the Win-Source product page for E2E-X10Y1-US.

Key Takeaways for Engineers & Buyers

  • Match the receiving input to SCR-NO, 2-Wire behavior before wiring E2E-X10Y1-US.
  • Budget target rate against the 25Hz response-frequency limit.
  • Reserve an M30 mount and specify cable-lead preparation for bulk-packed units.