Omron E2E-X12B1T18 2M: Active for new inductive designs

E2E-X12B1T18 2M Omron product image

10V ~ 30V supply bounds, 12 mm sensing distance, M18 thread, -25°C ~ 70°C operating range

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 12MM PNP M18 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V

Can this Omron sensor go into a new machine build?

Is it suitable for a new machine build? Yes. E2E-X12B1T18 2M is marked Active in both the lifecycle and product-status fields, with no conflict between them. Its status does not restrict it to sustaining designs, and it is listed as EU RoHS compliant.

The practical question is how to wire it. This sensor has cable leads rather than a connector, so set the termination method before releasing the assembly.

The M18 body fits only if the input and supply do

That termination leads to a PNP-NO, 3-wire output. The control input has to suit it, not just accept a proximity sensor. The listed 10V ~ 30V figures bound the supply; they do not select a rail or establish the output-load limit.

The threaded M18 body gives the mounting choice a starting point. Its shielded inductive construction points to machine-mounted metal-target detection, and the -25°C ~ 70°C operating range sets the temperature bounds for the installation. Neither the thread nor that range settles the required clearance around the body.

Does 500Hz clear the detection rate?

500Hz is the listed response-frequency ceiling. It rules out unlimited pulse detection but does not establish timing at the control input. Check the event rate before committing to E2E-X12B1T18 2M.

12 mm still needs a target trial

12 mm is the listed sensing distance, not a guarantee that every metal target will switch at that separation. Test the actual target at the intended distance: no target-material response information is listed to settle that question.

E2E-X12B1T18 2M also has no stated output-load limit here, and that limit is needed before assigning its PNP-NO output to a control input. A wiring diagram and dimensional drawing are absent, leaving conductor identification and mounting clearance open; those gaps cannot be closed by inferring details from the M18 thread.

View the Win-Source product page for E2E-X12B1T18 2M.

Key Takeaways for Engineers & Buyers

  • Test the actual target against the listed 12 mm sensing distance.
  • Check the machine ambient against the -25°C ~ 70°C operating range.
  • Set a cable-lead termination method before releasing the assembly.