12mm sensing distance, 10V to 30V supply limits, M18 body, and -25°C to 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 12MM PNP M18 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V |
An M18 inductive sensor is the wrong choice for nonmetal targets
This isn't a sensor for nonmetal targets or an unthreaded mounting hole. Omron's E2E-X12B3DL18 2M is an Active, shielded inductive sensor with an M18 threaded body. It suits new design-in where the target and mounting geometry match. EU RoHS compliance is listed.
The 500Hz figure does not settle event timing
The 500Hz response-frequency figure doesn't settle event timing: it gives no switching delay for a control sequence. The environmental case is clearer. IP67 and IP69K are listed, and the operating-temperature range is -25°C to 70°C. Those ratings support considering the sensor at an exposed industrial station, but they do not establish how the cable exit and mounting arrangement behave there.
A PNP input needs more than a supply-voltage match
Supply voltage is not enough. The 10V to 30V supply limits bound the rail, but output load drive and output voltage drop remain unspecified; a rail match alone cannot establish compatibility with a PLC input. The PNP-NC/NO, 3-Wire output identifies the interface category, while a wiring diagram is needed to assign the cable conductors and establish the intended output behavior.
The M18 threaded, shielded body establishes a mounting concept, not the dimensions needed to release a bracket. The wiring diagram, mechanical drawing, and output load rating are absent here; those are the items that close the electrical and mechanical fit. An LED provides local indication, not proof of input margin.
The 12mm reach still needs a target test
12mm is the listed sensing distance, not a promise that every target trips at that separation. Target correction data is absent, so test the actual material and fixture clearance before fixing the sensor position. It comes in box packaging with cable leads; match the specified termination to the station harness rather than assuming a connector is supplied. Keep E2E-X12B3DL18 2M on the new-build BOM once that termination is resolved.
View the Win-Source product page for E2E-X12B3DL18 2M.
Key Takeaways for Engineers & Buyers
- Get switching-delay data before timing an event around the 500Hz response frequency.
- Check the station rail against the 10V to 30V supply limits.
- Test the actual target and mounting at the listed 12mm sensing distance.