12mm inductive sensing, M18 threaded body, 10V ~ 30V supply, -25°C ~ 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 12MM PNP M18 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V |
Can this M18 sensor go on a new machine BOM?
Can this sensor go on a new machine BOM? Yes. E2E-X12B3DL18-M1 has Active lifecycle and product statuses, with no conflict among the listed signals. EU RoHS compliance is stated. Specify the connector-terminated, M18 threaded configuration, and don't mistake “Box” for an installation detail. Active status does not establish reliable switching in a particular fixture.
The supply rail must stay inside the listed bounds
The rail has limits. The listed 10V ~ 30V span puts 30V at the upper ceiling, not a working setpoint; check the machine rail against the 10V lower bound as well. If the cabinet supply falls outside that span, sensing distance is beside the point. The PNP-NC/NO, 3-Wire output also has to match the controller input: proper power alone cannot prevent the wrong signal.
A 12mm target distance is not universal clearance
This sensor is wrong for fixtures that assume every metal target will switch at a guaranteed 12mm clearance. The listed 12mm sensing distance is a layout starting point, not a settled trip position across target materials. Its shielded, M18 threaded body belongs in an industrial metal-detection position where the actual target can be tested. If the machine geometry prevents that mounting check, the sensing-distance figure cannot rescue the design.
500Hz sets a switching ceiling, not a detection guarantee
500Hz is the listed response-frequency ceiling. It does not guarantee that every passing target will register at that rate, so check target speed and geometry against switching behavior before a missed transition leaves the controller with a false position state. The -25°C ~ 70°C operating span is a separate limit: even with IP67 and IP69K ingress ratings, an enclosure approaching 70°C cannot be waved through. Ingress isn't thermal headroom.
The nickel-plated brass body and connector termination suit a mounted industrial sensor, but the ingress ratings alone do not establish whether the installed connection is sealed. That matters when washdown reaches the cable connection rather than just the sensor body.
The fixture still needs dimensions and switching details
A 12mm layout still leaves target-material behavior unresolved. The datasheet must supply the target-material correction curve, connector pinout, mechanical drawing and output load-current limit; none is listed here. Without them, mounting and wiring remain guesswork.
View the Win-Source product page for E2E-X12B3DL18-M1.
Key Takeaways for Engineers & Buyers
- Reserve an M18 threaded mounting position.
- Match the controller input to the PNP-NC/NO, 3-Wire output.
- Check target-metal behavior before fixing clearance around the listed 12mm sensing distance.