12mm sensing distance, 10V–30V supply limits, M18 thread and -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 12MM NPN M18 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new machine build
Active status can't tell you how to wire the sensor, but it supports Omron E2E-X12C118-R 5M as a candidate for a new machine build. The lifecycle signals agree. None points to a sustaining-only restriction. It is listed as EU RoHS compliant.
12mm reach sets the target check
12mm is the listed sensing distance, not a guarantee for every target at that clearance. Position the target before fixing the bracket. The 10V–30V supply limits bound the rail choice, but neither number supports operation outside that range, and the -25°C to 70°C operating range puts a separate boundary on the installation.
The M18 head needs the right input and target
Even within those limits, the NPN-NO, 3-Wire output needs an input arranged for that switching type; an input expecting normally closed operation would read the sensor state backwards. The shielded inductive head and M18 threaded body suit a metal-position checkpoint, not a nonmetallic target. IP67 and IP69K are listed ingress ratings, but they say nothing about how the cable termination is protected.
500Hz does not close the switching hookup
500Hz is the listed response frequency. Treat it as a ceiling when checking whether moving targets can be counted at the intended rate, not as a rating for the output load. That distinction matters before assigning the NPN-NO signal to an input circuit.
The output load-current limit and wiring diagram are absent. One determines whether the intended input can be driven; the other shows how the cable leads connect. A mechanical drawing is absent too. M18 identifies the thread, not the clearance around the sensing face or cable exit. The response-frequency figure cannot fill those gaps.
Cable leads rule out a connectorized drop-in
A connectorized drop-in is the wrong purchase. For a machine built around cable leads, order the boxed part and plan their routing and termination; the M18 thread alone won't settle installation.
View the Win-Source product page for E2E-X12C118-R 5M.
Key Takeaways for Engineers & Buyers
- Check target clearance against the listed 12mm sensing distance.
- Keep the supply within the listed 10V–30V limits.
- Plan the input connection for an NPN-NO, 3-Wire sensor with cable leads.