12mm sensing distance, 10V–30V supply, M18 thread and −25°C to 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 12MM NPN M18 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V |
An NPN input makes this M18 sensor worth considering
A controller input expecting a sourcing output is the wrong place for this sensor. For an input built around NPN-NO, 3-wire switching, E2E-X12C1L18 2M is a reasonable new design-in candidate: its lifecycle signals all say Active, and it is EU RoHS compliant. The M18 threaded, shielded body gives the mechanical choice a starting point.
The listed 12mm sensing distance sets the reach to screen against the target position, but it doesn't establish that reach for every target material or mounting arrangement. A missed target stops the count.
The supply window matters before the 500Hz response
That electrical fit still depends on the supply rail. The listed 10V–30V range rules out a rail outside that window, but it says nothing about allowable ripple or transients, so neither is covered by the stated range. The 500Hz response frequency helps screen moving-target detection; it does not establish switching behavior for the intended target and installation.
Operating temperature is listed as −25°C to 70°C. That range screens ambient temperature, not the complete mounted assembly's tolerance of site conditions. Keep that distinction separate from the NPN-NO output match.
Ingress ratings do not finish the installation details
The listing leaves out a wire-color pinout, an output-load current limit and a mounting drawing. Without them, the NPN-NO description cannot close the wiring check, and the M18 thread cannot settle mechanical clearance. Those are specific gaps, not details to guess.
IP67 and IP69K are useful listed ingress ratings for this industrial sensor. They do not establish protection at the installed cable exit or in the surrounding assembly.
Will cable leads fit the running line?
Does the line accept cable leads? This sensor has cable leads, not a connector. Put that termination and the M18 threaded body on the purchase specification; a line prepared for a connector would stop at installation.
View the Win-Source product page for E2E-X12C1L18 2M.
Key Takeaways for Engineers & Buyers
- Check the intended target against the listed 12mm sensing distance.
- Match the controller input to the NPN-NO, 3-wire output and 10V–30V supply.
- Specify cable leads and the M18 threaded body on the purchase line.