12mm sensing distance, 10V to 30V supply limits, threaded M18 body and NPN cable-lead output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 12MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V |
NPN output and cable leads narrow the machine fit
This sensor is wrong for a PNP input or a station that requires a connectorized sensor. E2E-X12C318 2M fits a threaded M18 mount and uses an NPN input with a 3-wire hookup. A matching thread won't fix a mismatched input. Its shielded inductive construction suits metal-target detection. The LED gives local indication, but it doesn't show what the controller sees.
On a machine where a missed detection stops motion, the input circuit and target position matter as much as the hole in the bracket. Omron marks the sensor Active in both lifecycle and product status, with no conflict listed, so new design-in is reasonable where it fits. EU RoHS compliance is listed.
Supply bounds, target reach and event rate set the limits
Electrical limits and target placement need separate checks. The listed 10V to 30V supply range sets the bounds; 30V is a ceiling, not a voltage to aim for. The 12mm sensing distance is a listed reach, not permission to leave a 12mm gap regardless of target material or mounting. The 500Hz response-frequency figure screens event rate but does not establish switching timing for a particular target. Events beyond that limit rule this sensor out.
The 70°C ceiling includes the installed sensor
-25°C to 70°C is the stated operating-temperature range. The 70°C upper bound applies to the installed sensor, not just the enclosure; a hot mounting position can take it outside the listed range.
Can the line terminate cable leads?
Can the line terminate cable leads? E2E-X12C318 2M is listed with cable leads and Box packaging, not a connector termination. A station built around plug-in sensors needs a lead-termination step in its assembly instructions. That wiring change is the practical buying constraint, even though the lifecycle status supports new builds.
The M18 thread still needs a drawing
Even after the wiring fits, the M18 thread leaves mechanical questions. A dimensional drawing and cable-lead pinout are absent from the listing. So are the NPN output current limit and sensing-distance data by target material, leaving input loading and a marginal target gap unresolved.
View the Win-Source product page for E2E-X12C318 2M.
Key Takeaways for Engineers & Buyers
- Compare target travel with the listed 12mm sensing distance.
- Check the controller supply against the 10V to 30V supply limits.
- Obtain the NPN output current limit before assigning an input load.