Omron E2E-X12C318 5M: Active for new industrial designs

E2E-X12C318 5M Omron product image

12mm sensing limit, 10V ~ 30V supply range, M18 threaded body, -25°C ~ 70°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 12MM NPN M18 NO/NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new sensor station

Active status supports new design-in. Omron E2E-X12C318 5M is marked Active in both lifecycle and product-status fields, with no conflict between them. EU RoHS is marked compliant. Electrical integration remains the open decision.

The M18 body fits a wired metal-target station

It won't suit a PNP input or a mounting hole that cannot accept an M18 threaded cylinder. The shielded inductive head and NPN-NC/NO, 3-wire output fit a metal-target station with a controller wired for that output, but cable leads require a planned termination rather than a connector mating step. IP67 and IP69K are listed protection grades; neither specifies how to install the cable exit.

Will the cable-lead version match the build?

Does the ordered sensor have cable leads? Omron E2E-X12C318 5M is listed with cable leads and a Box package, and its lifecycle fields agree on Active. Put the full identifier and cable-lead termination on the purchase order. An M18 body can mount correctly and still stall assembly if the harness expects a connector.

The 12mm limit does not settle target timing

12mm is the listed sensing-distance limit, not a promised switching point for every target; leaving no allowance for target variation risks missed detections. The listed supply range runs from a 10V lower bound to a 30V ceiling, not a nominal setpoint. A rail outside that range rules out the installation. The 500Hz response-frequency listing is a ceiling, not a timing waveform that proves closely spaced targets will be counted.

Operating temperature is listed at -25°C ~ 70°C. That range sets an environmental boundary, not an enclosure-temperature margin. Output-load current is absent, so the controller input and pull-up cannot yet be sized from this listing. Cable-lead wiring assignments and a dimensional drawing are also missing; the harness and mount need those details before release.

View the Win-Source product page for E2E-X12C318 5M.

Key Takeaways for Engineers & Buyers

  • Match the controller input to the NPN-NC/NO, 3-wire output.
  • Keep the supply within the listed 10V ~ 30V range.
  • Reserve an M18 threaded mount and a cable-lead termination.