12mm sensing limit, 10V ~ 30V supply range, M18 threaded body, -25°C ~ 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 12MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new sensor station
Active status supports new design-in. Omron E2E-X12C318 5M is marked Active in both lifecycle and product-status fields, with no conflict between them. EU RoHS is marked compliant. Electrical integration remains the open decision.
The M18 body fits a wired metal-target station
It won't suit a PNP input or a mounting hole that cannot accept an M18 threaded cylinder. The shielded inductive head and NPN-NC/NO, 3-wire output fit a metal-target station with a controller wired for that output, but cable leads require a planned termination rather than a connector mating step. IP67 and IP69K are listed protection grades; neither specifies how to install the cable exit.
Will the cable-lead version match the build?
Does the ordered sensor have cable leads? Omron E2E-X12C318 5M is listed with cable leads and a Box package, and its lifecycle fields agree on Active. Put the full identifier and cable-lead termination on the purchase order. An M18 body can mount correctly and still stall assembly if the harness expects a connector.
The 12mm limit does not settle target timing
12mm is the listed sensing-distance limit, not a promised switching point for every target; leaving no allowance for target variation risks missed detections. The listed supply range runs from a 10V lower bound to a 30V ceiling, not a nominal setpoint. A rail outside that range rules out the installation. The 500Hz response-frequency listing is a ceiling, not a timing waveform that proves closely spaced targets will be counted.
Operating temperature is listed at -25°C ~ 70°C. That range sets an environmental boundary, not an enclosure-temperature margin. Output-load current is absent, so the controller input and pull-up cannot yet be sized from this listing. Cable-lead wiring assignments and a dimensional drawing are also missing; the harness and mount need those details before release.
View the Win-Source product page for E2E-X12C318 5M.
Key Takeaways for Engineers & Buyers
- Match the controller input to the NPN-NC/NO, 3-wire output.
- Keep the supply within the listed 10V ~ 30V range.
- Reserve an M18 threaded mount and a cable-lead termination.