12mm sensing distance, 10V–30V supply limits, M18 thread and cable leads set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 12MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V |
Active status makes the inductive sensor a new-design option
That settles the lifecycle side: E2E-X12C318-R 5M is Active, with no conflict in the listed status fields. It’s a new-design option, not a sustaining-only choice. Its inductive sensing and shielded M18 threaded body point to a machine-mounted metal target, provided the input circuit matches the NPN-NC/NO output. EU RoHS compliance is listed.
The 12mm sensing distance makes target position the first fit question, but it does not establish distance for every target material or mounting arrangement. A target that fails to trigger reliably becomes a machine fault, not a catalog discrepancy.
Supply limits and response frequency bound the electrical fit
The 10V–30V supply range sets a hard circuit limit: 30V is a ceiling, not a working setpoint, and a rail outside the range rules out the part. The listed 500Hz response frequency helps screen moving-target applications, but it does not specify the turn-on or turn-off delay needed to settle timing at the controller input.
Operating temperature is listed from -25°C to 70°C. The upper endpoint is a limit, not a reason to overlook heat at the mounted sensor. The NPN-NC/NO, 3-wire output identifies the input style to plan around.
Will the M18 cable-lead build match the installed hardware?
Will the cable leads suit the machine’s wiring? That is the buying question for E2E-X12C318-R 5M. The threaded cylindrical body commits the machine to an M18 mounting position, while the cable leads require a wired termination rather than a mating sensor connector. Before release, put both on the BOM and check the cable route, because an electrically suitable sensor can still halt assembly if its connection can’t be installed.
The listed package is Box; it says nothing about the sensor’s mounting or termination. Its nickel-plated brass body and IP67, IP69K ingress ratings support considering it for exposed industrial equipment, but those labels do not settle sealing at the cable exit in a particular installation. The LED gives a local indication. It cannot establish that the controller sees the intended NPN state.
The M18 fit is stated; the installation details are not
The gaps are at the handoff to hardware, not in the stated M18 thread. No wiring diagram or output load rating is listed. A dimensioned drawing and target-dependent sensing curve are also absent, leaving input wiring, mounting clearance and usable sensing distance unresolved.
View the Win-Source product page for E2E-X12C318-R 5M.
Key Takeaways for Engineers & Buyers
- Check the 12mm sensing distance against the actual target and mount.
- Keep the supply within the listed 10V–30V limits.
- Specify the M18 threaded body and cable leads on the BOM.