14mm sensing distance, 10V–30V supply bounds, M18 body, -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM PNP M18 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
The 14mm reach makes this an Active design-in candidate
14mm is the listed sensing distance for E2E-X14B1D18 5M, not a promise that every target at that gap will switch. It gives a starting point for placing the inductive sensor; the target and mounting arrangement still determine whether detection is reliable. The 10V lower supply bound and 30V upper ceiling help screen the control rail, but neither establishes what load the PNP output can drive.
The lifecycle signals all say Active, making this a candidate for new design-in as well as existing production. It is listed as EU RoHS compliant.
350Hz may be the counting constraint
Brief target passes may go uncounted. The listed 350Hz response-frequency ceiling calls for a test with the actual event pattern. IP67 and IP69K support use on exposed machinery, but they don't establish resistance to the plant's cleaning chemicals.
M18 mounting works only with the right input and cable route
A sinking input is the wrong match. This sensor's PNP-NO, 3-Wire output belongs with an input wired for a sourcing, normally-open signal; get that logic wrong and the machine reads the wrong event. The M18 threaded cylinder calls for a machine bracket rather than a board footprint, while the cable leads need a protected route away from moving hardware. A bracket can fit the body and still leave no workable cable path.
Shielded construction matters near surrounding metal, but “shielded” does not specify mounting clearance. The listed operating range of -25°C to 70°C sets the environmental boundary for this selection; outside it, these specifications give no basis to count on detection or output behavior. This is a metal-detection choice for an industrial installation, not a general object sensor.
The M18 callout does not finish the installation
And even then, the bracket decision needs a mechanical drawing: M18 alone gives neither overall length nor cable-exit clearance. The datasheet must also supply the wiring diagram, output load limit and target-dependent sensing data before the installation can be settled.
For an existing production line, keep the cable-lead termination on the build specification and obtain the drawing before changing the bracket.
View the Win-Source product page for E2E-X14B1D18 5M.
Key Takeaways for Engineers & Buyers
- Check the target geometry against the listed 14mm sensing distance.
- Test the event rate against the 350Hz response-frequency ceiling.
- Keep the M18 bracket and cable-lead termination on the build specification.