Omron E2E-X14B1D18-R 5M: Active for New Designs

E2E-X14B1D18-R 5M Omron product image

14mm sensing distance, 10V ~ 30V supply limits, and an M18 threaded body with cable leads.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 14MM PNP M18 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new M18 sensor design-in

That leaves E2E-X14B1D18-R 5M open to new design-in rather than restricting it to sustaining production: the lifecycle signals agree on Active, and EU RoHS compliance is listed. The 14mm sensing distance is a starting point for target placement, not proof that the intended target will switch at that gap. The 10V ~ 30V supply limits bound the control rail but do not establish a preferred operating voltage. A rail outside those limits rules the sensor out before mechanical fit matters.

Will cable leads work on the running line?

Will the existing assembly accept cable leads instead of a connectorized sensor? That is the immediate buying question for this boxed, M18 threaded version. Match the termination and mounting arrangement to the approved assembly before releasing E2E-X14B1D18-R 5M to a running line; Active status doesn't make a wiring change harmless. Its PNP-NO, 3-wire output must match the control input, or the machine will read the wrong switching behavior.

PNP-NO output rules out the wrong control input

An input expecting a different output type rules this sensor out. It belongs at an industrial inductive sensing point with an M18 threaded mount and a control input for its PNP-NO, 3-wire output. Its shielded body and listed IP67 and IP69K protection help identify the installation, but they do not settle the target position.

350Hz cannot settle event capture by itself

350Hz is the listed response frequency. It offers a first check against passing targets, but the frequency alone does not guarantee that a particular event will be captured on the running line. The operating-temperature range of -25°C ~ 70°C sets the stated ambient bounds, not switching behavior at either end. A missed detection could become a line fault.

The missing details matter. The output load limit is needed to size the PNP input circuit. Wire identification is needed to connect the cable leads, while a mounting drawing is needed to place the M18 body. Sensing-distance behavior with the intended target is also absent. The 14mm listing can't close those gaps.

View the Win-Source product page for E2E-X14B1D18-R 5M.

Key Takeaways for Engineers & Buyers

  • Check the 14mm sensing distance against the intended target position.
  • Keep the control rail within the listed 10V ~ 30V supply limits.
  • Test event capture against the listed 350Hz response frequency.