14mm sensing distance, 10V to 30V supply, M18 body; target clearance decides the installation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM PNP M18 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
The 14mm sensing distance makes target placement the first test
Target clearance comes first. The listed 14mm sensing distance does not establish a guaranteed switching point for every metal target, so a target placed at that boundary can fail to register on the machine. E2E-X14B1T18 5M is a candidate for new design-in for inductive presence detection, not a distance-measurement device. Its lifecycle signals agree on Active, with no conflict for new or existing production; EU RoHS compliance is listed.
The shielded M18 threaded body sets the mounting form, but the bracket still has to put the sensor face in the target’s path. The PNP-NO, 3-wire output must match the machine input. Neither Active status nor an LED indication can fix a missed target.
The 10V to 30V supply range excludes rail excursions
10V to 30V is the listed supply range, not a setpoint. A rail outside those bounds rules this sensor out. The listed operating temperature range is -25°C to 70°C; its 70°C upper limit does not establish headroom beside a hotter process.
A fast target can outrun the 350Hz response rating
Fast events that demand switching beyond 350Hz rule this sensor out: the listed response frequency doesn’t support a higher event rate. At a fixed metal-target station, the shielded M18 cylinder and listed 14mm sensing distance offer a plausible arrangement if the bracket can hold the required clearance. That distance alone does not prove switching with the chosen target. IP67 and IP69K are listed ingress ratings, useful when selecting for wet equipment, but they do not establish the protection of the finished cable installation.
Cable leads settle the order, not the wiring
And the cable isn’t the only unfinished detail: a dimensioned drawing and wiring pinout are absent, along with the output load limit needed to check the PNP-NO interface. Get those items before releasing the mounting and electrical details. E2E-X14B1T18 5M has cable leads; specify that termination on the purchase line. Box describes its packaging, not a connector option.
View the Win-Source product page for E2E-X14B1T18 5M.
Key Takeaways for Engineers & Buyers
- Check target clearance against the listed 14mm sensing distance.
- Keep the supply within the listed 10V to 30V range.
- Compare the machine’s event rate with the listed 350Hz response frequency.