14mm inductive sensing, 10V to 30V supply bounds, M18 body and -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM PNP M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
The 14mm reach decides the first cut
A 14mm reach and M18 thread make target position and mounting-hole fit the first tests for this inductive sensor. E2E-X14B218 5M is an Active new-design candidate and is listed as EU RoHS compliant. A control input requiring normally-open behavior rules out its PNP-NC output.
Supply bounds and target speed set the hard limits
The rail must fit. The 10V to 30V supply bounds decide whether the control rail can feed this sensor; neither endpoint establishes tolerance for supply transients. The listed 14mm sensing distance is a geometry gate, not a promise of that reach against every target material.
At 350Hz, the listed response-frequency ceiling rules out treating faster target events as reliably countable, but it does not establish switching latency for a moving target. The -25°C to 70°C operating range sets 70°C as the upper ceiling and -25°C as the lower bound; a machine outside either bound is outside the stated range even if its target speed is acceptable.
A shielded M18 body belongs on the machine
That still leaves the mounting argument: the nickel-plated brass M18 threaded body and cable leads suit a machine bracket with a routed connection to a PNP-compatible input, not a socket intended for a plug-in sensor. Shielding matters where metal crowds the sensing face. IP67 and IP69K ingress ratings make wet machinery a plausible setting, but they do not establish chemical compatibility for a particular cleaning process.
Cable leads, not a plug-in termination
Does the build need a connector? E2E-X14B218 5M comes in a Box and terminates in cable leads. A Box isn't the machine connection. Match the assembly instruction to a routed, terminated cable before releasing the part on a new bill of materials; a build expecting a plug-in sensor needs a different termination plan.
The PNP load limit is still missing
The output-current limit is missing, although the supply bounds are stated. Without that limit, the PNP-NC output cannot be checked against its intended load. The datasheet must also supply wire assignments and a mechanical drawing: cable leads don't identify conductor functions, while M18 alone does not settle sensing-face position or bracket clearance. A target-material correction curve would close the remaining question about detection distance on the actual target.
View the Win-Source product page for E2E-X14B218 5M.
Key Takeaways for Engineers & Buyers
- Check the control rail against the 10V to 30V supply bounds.
- Match the M18 threaded body to the machine bracket.
- Obtain the PNP-NC output-current limit before assigning its load.