Omron E2E-X14B218-R 5M: Active for new design-in

E2E-X14B218-R 5M Omron product image

14mm sensing distance, 10V ~ 30V supply, M18 body and -25°C ~ 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 14MM PNP M18 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V

A normally-open input rules out this Omron sensor

A controller expecting a normally-open switch rules this sensor out. Omron’s E2E-X14B218-R 5M is an inductive, shielded M18 threaded sensor with a PNP-NC, 3-wire output. It belongs where that switching behavior matches the controller input and a metal target passes the sensing face. The nickel-plated brass body and IP67/IP69K ratings support exposed industrial mounting, but don't establish how the cable termination will be sealed.

The 14mm reach matters more than the 350Hz figure

The 350Hz response frequency can't clear a fast target sequence by itself; it does not establish the timing of a target passing this installation. The 14mm sensing distance is the proposed standoff ceiling, not a guarantee of detection at that distance for every target material. Get the standoff wrong and the machine may miss a target that looks close enough on a drawing.

The 10V ~ 30V supply range sets the rail limits: 30V is a ceiling, not a working setpoint, and a supply outside the range rules out direct connection. The -25°C ~ 70°C operating-temperature range sets the site boundary. If the enclosure exceeds its 70°C ceiling, the sensor needs another location.

Active status supports the design-in, not the cable work

New design-in is defensible. E2E-X14B218-R 5M is marked Active across the lifecycle fields, with no conflicting signal, and is EU RoHS compliant. Box packaging and cable leads put termination on the assembly process; specify the lead connection in build instructions before release to the line.

The wiring and target curves still decide release

Nor does that instruction resolve the lead connection: no wiring diagram identifies the cable conductors, and no output load-current rating establishes what the PNP output may drive. Obtain both before assigning a controller input or load. A target-material sensing curve and mechanical drawing are also absent; the listed reach and M18 thread cannot settle actual target clearance or the full mounting envelope. Those gaps leave the installation details open.

View the Win-Source product page for E2E-X14B218-R 5M.

Key Takeaways for Engineers & Buyers

  • Match the PNP-NC, 3-wire output to the controller input.
  • Keep the supply within 10V ~ 30V; treat 30V as the upper limit.
  • Set target standoff against the listed 14mm sensing distance.