14mm sensing distance, 10V ~ 30V supply range, M18 body and -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM PNP M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
An M18 metal-target station, not a nonmetal detector
Nonmetal targets are the wrong job for this inductive sensor. The 14mm sensing distance is a listed limit rather than a guaranteed gap for every metal target, so target geometry still determines whether the fixture will work. The shielded M18 threaded body suits a machine-mounted detection point, and the PNP-NC, 3-wire output needs an input that accepts its signal and logic. IP67 and IP69K ingress ratings help with enclosure selection, but they don't settle sealing at the cable entry in the assembled machine.
Active status clears the lifecycle question, not the rail limits
New design-in is reasonable. The Active lifecycle signals agree for E2E-X14B2L18 5M, and EU RoHS compliance is listed.
The 10V ~ 30V supply range sets the rail boundaries, not a preferred setpoint. Above 30V exceeds the listed ceiling; below 10V falls outside the stated range. The -25°C ~ 70°C operating-temperature range also bounds the installation choice, but it does not establish the temperature at the sensor's mounting point in a running machine.
Will the build accept cable leads?
Cable leads or a mating connector? This sensor uses cable-lead termination. Set the cable route and termination method before releasing a harness designed around a connector; box packaging isn't the line-build constraint.
350Hz leaves the switching and wiring questions open
350Hz is the listed response frequency, not a switching waveform or proof of detection at every target geometry. The output load-current rating is absent, leaving the receiving input and any interface load unsettled. A wiring diagram is also absent: PNP-NC, 3-wire identifies the output scheme, not the individual conductor assignments.
Target-material correction data and hysteresis are missing, so the actual trip point and release behavior remain open despite the listed sensing distance. There is no mounting drawing either. The M18 thread callout establishes the mounting format, but not the full envelope or clearance needed around the installed sensor.
View the Win-Source product page for E2E-X14B2L18 5M.
Key Takeaways for Engineers & Buyers
- Check target geometry against the listed 14mm sensing distance.
- Keep the supply within the listed 10V ~ 30V range.
- Obtain the missing output load-current rating before selecting the input circuit.