14mm sensing distance, 10V to 30V supply limits, M18 body, -25°C to 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 14MM NPN M18 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V

14mm reach makes the target the first fit decision

14mm is the listed sensing-distance limit. It isn't a guaranteed switching gap for every metal target: a target passing farther away cannot be counted on to trip the sensor. The shielded, threaded M18 body needs a bracket that holds the gap and cannot replace a sensor with a different mounting thread. IP67 and IP69K are listed ingress ratings, but they do not settle how the cable entry will perform once installed.

Active status supports a new inductive-sensor design-in

Design it in. E2E-X14C118 5M is marked Active in both lifecycle and product status, with no stated conflict, and is listed as EU RoHS compliant. That clears the lifecycle objection to a new design, not the electrical interface.

The 10V to 30V supply limits exclude a rail outside that range, while the NPN-NO, 3-Wire output calls for an input wired for that switching arrangement. A 350Hz response-frequency ceiling bounds the event rate; it is not a measured switching delay. The -25°C to 70°C operating range sets the temperature bounds for the machine environment. Get the electrical interface or event rate wrong and the sensor may fail to switch the input or miss an event, even if its M18 body fits the bracket.

Can the cable-lead version stay on the running line?

Will this cable-lead version work on the running line? It has cable leads and comes in a box, with no connector interface listed. Keep the cable-termination instructions with E2E-X14C118 5M on the production BOM so an assembler does not mistake an M18 mechanical match for an electrical match. Active status supports continued use in existing production; the line still needs a controlled connection from this NPN-NO output to the input.

The 14mm limit still leaves the switching gap open

The 14mm limit leaves the actual switching gap unresolved. A target-material correction curve is absent, as are a wiring diagram and mounting drawing. Those missing items govern the target check, NPN-NO termination and M18 placement.

View the Win-Source product page for E2E-X14C118 5M.

Key Takeaways for Engineers & Buyers

  • Check the actual target and gap against the 14mm sensing-distance limit.
  • Match the input to the NPN-NO, 3-Wire output before terminating the cable leads.
  • Compare event rate with the 350Hz listed response ceiling.