A 14mm sensing distance in a shielded M18 body; check the NPN-NO interface and operating limits.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM NPN M18 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new inductive-sensor design
Design it in. E2E-X14C1L18 2M is marked Active in both the lifecycle and product-status fields, with no conflicting signal; its status leaves it open for new designs. The NPN-NO output is a firm interface choice: a controller input expecting different switching behavior will miss the event even if the sensor fits the machine. It is listed as EU RoHS compliant.
The 14mm reach needs more scrutiny than the M18 thread
The 14mm sensing distance is the first constraint: it guides target spacing but doesn't establish reach for every target material or mounting arrangement. A shielded M18 threaded body gives the layout a starting point, not a completed mounting check; keep the sensing face and target position in view before fixing the bracket.
The 350Hz response-frequency ceiling rules out assuming faster detection, but it gives no response time for a moving target, so the timing question remains open. The 10V ~ 30V supply bounds define the allowable rail range; excursions beyond it are not covered. The -25°C ~ 70°C operating-temperature range applies inside those bounds, not outside them.
Cable leads settle the ordering choice
3-Wire NPN-NO with cable leads is the BOM configuration. Specify cable termination rather than assuming a plug-in sensor; box packaging doesn't change the connection the machine must accommodate.
A metal-target pickoff still needs mounting and wiring details
Wrong for a nonmetal target or an installation that requires a plug-in sensor. A shielded M18 cylinder instead belongs at a machine-mounted metal-target pickoff. IP67 and IP69K are listed ingress ratings, but leave protection at the cable termination in the finished assembly unresolved.
The wiring diagram and mounting drawing are absent, as is the output load-current limit needed to check the controller input load. Wiring and mechanical layout remain open.
View the Win-Source product page for E2E-X14C1L18 2M.
Key Takeaways for Engineers & Buyers
- Set target spacing against the listed 14mm sensing distance.
- Match the controller input to the 3-Wire NPN-NO output.
- Keep the supply within the listed 10V ~ 30V bounds.