14mm sensing ceiling, 10V–30V supply bounds, M18 mounting, -25°C to 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM NPN M18 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
Active status leaves cable termination as the line constraint
Nor is lifecycle the obstacle: E2E-X14C1L18 5M is Active across the recorded status fields, with no conflict, so new design-in is reasonable. EU RoHS compliance is stated. Cable leads, not the Box packaging designation, set the assembly constraint; specify their termination in line instructions.
The 14mm reach cannot settle target placement alone
Target placement has a hard limit. The listed 14mm sensing distance is a ceiling, not a guarantee of reliable detection at that gap across targets and mounting conditions. The 10V to 30V supply bounds make 30V a ceiling, not a preferred operating point; they don't establish tolerance to rail transients. The -25°C to 70°C operating-temperature range bounds the sensor environment, not the temperature of a nearby process surface. A mounting position that ignores those limits can miss targets or cause an electrical fault.
M18 mounting and NPN-NO output narrow the fit
The fit is narrow. It's a fixed-mount sensor. E2E-X14C1L18 5M has an M18 threaded cylinder and a shielded inductive sensing arrangement, making it a candidate for a metal-target station with controlled mounting geometry, not a claim of detection for nonmetal targets. Its NPN-NO, 3-Wire output needs a matching controller input; the output description alone does not establish interchangeability with another sensor's wiring. IP67 and IP69K are listed ingress ratings, but the cable termination remains part of the installed assembly.
350Hz still needs a motion check
350Hz is the listed response frequency, not proof that every passing target will register. The missing response-frequency test conditions and target-dependent sensing curves leave passage timing and the usable sensing gap unsettled. A wiring diagram and dimensioned M18 drawing are also absent, leaving the controller connection and mechanical clearance open before release.
View the Win-Source product page for E2E-X14C1L18 5M.
Key Takeaways for Engineers & Buyers
- Keep target placement inside the 14mm listed sensing-distance ceiling; obtain target-specific curves.
- Match the controller input to NPN-NO, 3-Wire before terminating the cable leads.
- Check the enclosure against the -25°C to 70°C operating-temperature range.