14mm sensing ceiling, 10V–30V supply limits, threaded M18 body and NPN-NC cable output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM NPN M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new machine build
Cable leads complicate a connectorized harness, but E2E-X14C218-R 2M is listed Active across its lifecycle fields, with no stated conflict. It remains a new design-in candidate where a cable-terminated sensor fits; the termination is a fit decision, not a reason to treat the part as sustaining-only. EU RoHS compliance is listed.
The 14mm gap decides more than the 350Hz figure
14mm is the listed sensing-distance ceiling, not a gap to assume will work with every target. Set the sensor position against that limit first. A target that fails to reach the sensing zone can be missed regardless of how quickly the controller reads the output.
For a moving target, the 350Hz response-frequency ceiling can screen the intended event rate, but it doesn't establish switching timing or rescue a target that fails to reach the sensing zone. The listed supply limits are 10V to 30V; a rail outside them rules out this sensor before input logic matters. Its stated operating-temperature range is -25°C to 70°C. A location beyond either end needs another part, not an assumed margin.
Cable leads set the purchasing action
Cable leads need a plan. E2E-X14C218-R 2M comes with cable leads and is packaged in a box; define the machine-side termination before releasing the build.
An NPN-NC input fits; a PNP-only input does not
A PNP-only controller input won't work with this 3-Wire NPN-NC sensor. It fits where an inductive sensor can sit in a threaded M18 mount and the controller expects a normally closed NPN output. The shielded body and listed IP67 and IP69K ingress ratings help define the installation, but they do not settle cable-entry protection.
Output-load current is missing, leaving the input-circuit check open. A wiring diagram and dimensional drawing are also needed to finish the connection and mounting layout. Without target-material correction data, the 14mm sensing ceiling alone cannot settle the target gap.
View the Win-Source product page for E2E-X14C218-R 2M.
Key Takeaways for Engineers & Buyers
- Check the target gap against the 14mm sensing-distance ceiling.
- Match the controller input to the 3-Wire NPN-NC output.
- Reserve mounting clearance for the threaded M18 body.