14mm sensing distance, 10V ~ 30V supply, M18 thread; NPN-NC, 3-wire output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 14MM NPN M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 350Hz; Voltage - Supply: 10V ~ 30V |
An active M18 sensor, if the input expects normally closed
So reach isn't enough to choose this sensor. E2E-X14C2L18 5M is listed Active, with no lifecycle conflict, and is a reasonable new design-in for industrial metal detection when the controller input expects an NPN-NC, 3-wire output. If the input expects a different output state, the installation fails before sensing distance matters. EU RoHS compliance is listed.
The threaded M18 body and cable leads make this a particular mechanical and wiring choice, not a generic proximity-sensor slot. For an existing production line, keep that cable-lead configuration explicit on the BOM: a connector-based assembly would need a different wiring plan. Box packaging does not settle that interface.
The 14mm distance sets the placement check
14mm is the listed sensing-distance ceiling, not a guaranteed trip point for every metal target. Target material and installation clearance still matter. Shielding doesn't settle the mounting position.
10V ~ 30V supply limits come before the 350Hz response ceiling
10V ~ 30V sets the listed supply boundaries. The control rail has to stay within them, but that range does not establish output loading. The 350Hz response frequency is a ceiling for the event rate, not a promise about switching delay at every installation condition. Miss that distinction on a fast-moving target and detections can be lost.
The stated operating-temperature range is -25°C ~ 70°C. It bounds the stated environment without resolving cable routing or mounting behavior at those extremes.
The cable wiring and output load still need answers
Wiring is not ready. The cable-lead assignment is absent, as is an output-current limit for checking the controller input load. A dimensioned mounting drawing is also absent. Get those items before fixing the harness and M18 mounting position.
View the Win-Source product page for E2E-X14C2L18 5M.
Key Takeaways for Engineers & Buyers
- Check the metal target and mounting position against the listed 14mm sensing distance.
- Keep the event rate below the listed 350Hz response ceiling.
- Obtain the cable-lead assignment before wiring the NPN-NC input.