Omron E2E-X14MD1 2M: Active, but RoHS status conflicts

E2E-X14MD1 2M Omron product image

14mm sensing distance, 12V ~ 30V supply limits, M18 threaded body, -40°C ~ 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageCylinder, Threaded - M18
Core functionSENSOR PROX
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NO, 2-Wire; Voltage - Supply: 12V ~ 30V

Active status permits design-in; the RoHS conflict does not

Active status is clear. E2E-X14MD1 2M remains a candidate for new design-in, but its compliance entries disagree: one says RoHS Compliant, while another says RoHS Non-Compliant. Resolve the conflict before approving the part for a build requiring EU RoHS compliance.

For existing production, the lifecycle status alone gives no reason to plan a migration. The compliance conflict still matters; BOM approval can't rest on whichever entry reaches the purchasing record.

The 14mm sensing distance is the first placement test

That leaves the listed 14mm sensing distance as the next test. It gives the mechanical layout a starting point, not a guarantee that the intended target will switch at 14mm in the finished assembly. The unshielded inductive sensor and M18 threaded body must be assessed in their actual mounting position, where treating the listed distance as unconditional clearance could leave a machine input that never changes state.

The 12V lower and 30V upper supply limits bracket the rail choice; 30V is a ceiling, not a working setpoint. The -40°C ~ 85°C operating range sets the temperature boundary for the installation but does not settle sensing behavior at either end. The NO, 2-wire output must also suit the controller input. A matching supply rail alone doesn't establish that match.

The M18 body fixes the mounting approach

The M18 threaded body sets a mounting constraint. Cable leads put the electrical connection beyond the body rather than at a connector on it. IP67 is the listed ingress-protection rating; it does not extend that protection to every cable termination in the installation. With bulk packaging, handling and assembly also matter to a running line. Establish how the sensor and its leads will be mounted and terminated before committing the station layout.

Fast switching needs evidence this entry lacks

Fast-event counting is the wrong job to approve from these figures; inductive presence sensing is more plausible. Response frequency is absent, as are an output-load limit and a wiring diagram. Those gaps determine whether the NO, 2-wire signal will work with the intended input.

View the Win-Source product page for E2E-X14MD1 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting EU RoHS entries before approving E2E-X14MD1 2M.
  • Check the 14mm sensing distance at the intended target position.
  • Match the 12V ~ 30V supply limits and NO, 2-wire output to the controller input.