14mm sensing distance, 10V ~ 30V supply bounds, M18 threaded body and -25°C ~ 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 14MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
The unshielded head needs room around the mounting face
An unshielded head makes a flush fit a poor assumption. Still, E2E-X14MD1-M1 is a sensible new design-in candidate for industrial metal-target sensing: its lifecycle signals agree on Active, and EU RoHS compliance is listed. The threaded M18 body gives the installer a defined mounting form, but it does not establish how much clearance the sensor face needs in the machine.
The listed reach matters only if the input matches
That mounting choice only helps if the target and control input match. The 14mm listed sensing distance sets the target-spacing check; it is not a promise of detection for every metal or mounting arrangement. Get the distance wrong and the input may never change. The 10V ~ 30V supply bounds constrain the rail without nominating a preferred operating voltage. The NPN-NO, 2-Wire output needs a matching controller input. Don’t wire it as a different output topology.
Can bulk packing work on this sensor’s assembly line?
How will we handle bulk packing? With E2E-X14MD1-M1 specified as Bulk, receiving and kitting instructions need to cover threaded sensors rather than assume a carrier format that has not been established. Settle that purchasing constraint before a running line adopts the sensor. Connector termination affects the cable assembly step, but “connector” alone can’t settle cable selection.
The -25°C ~ 70°C operating-temperature range sets the installed-location check; it says nothing about operation outside those bounds. IP67 gives the sensor an ingress-protection designation, not a claim about the seal of a completed connector joint during washdown. The LED can help locate a sensing fault at the machine. The controller input still decides whether the signal is usable.
400Hz does not settle short-event detection
400Hz is the listed response frequency, not a turn-on or turn-off waveform. Response-time detail is absent. Settle the pinout, connector mating details and mounting-clearance drawing before releasing wiring and face placement.
View the Win-Source product page for E2E-X14MD1-M1.
Key Takeaways for Engineers & Buyers
- Trial the actual target at the listed 14mm sensing distance.
- Match the 10V ~ 30V supply bounds and NPN-NO, 2-Wire input.
- Set bulk handling instructions for the threaded sensor.