10V–30V supply limits, 14mm sensing distance, M18 body, -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIV 14MM CYL 5M |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
An unshielded M18 sensor is a poor flush-mount assumption
Flush mounting is the wrong starting point for an unshielded M18 cylinder: surrounding metal can affect detection, so test with the existing bracket rather than judging fit by the sensor thread alone. At the installed gap, the listed 14mm sensing distance makes E2E-X14MD1S 5M worth testing, but it doesn't promise a switch for every target. Inductive sensing is for metal-target presence checks, not nonmetal detection.
The NPN-NO, 2-Wire output has to match the installed input circuit; a mismatch can leave the controller blind to the target. IP67 describes the sensor’s ingress-protection rating, not the cable-lead connection. The LED gives a local indication, not proof of the signal arriving at the controller.
The rail, ambient and event rate set separate limits
Rail voltage sets a hard boundary. The listed 10V to 30V supply range brackets the rail, with 30V a ceiling rather than a working target; it does not establish an allowable output load current. The -25°C to 70°C operating-temperature range makes 70°C the upper limit at the sensor, not a cabinet-air allowance.
The 400Hz response-frequency figure is a ceiling for expected event rate, not a switching waveform. Events above that ceiling risk missed detections. These limits can rule out an installed rail or machine cycle, but they can't prove detection at the actual mounting gap.
The Active flag does not cancel EOL
No new design-in. E2E-X14MD1S 5M carries an EOL lifecycle status while Product Status says Active; the Active flag does not settle that conflict. Keep it to sustaining existing production, secure inventory and plan migration. Its EU RoHS-compliant marking does not change the lifecycle decision.
M18 and cable leads narrow the fit, not the wiring
Connection detail is the weak point: the 2-Wire NPN-NO label does not settle how the sensor connects to the controller input. M18 and cable leads do narrow the physical fit. A mounting drawing and pinout still have to settle installation; a response-time waveform and output load-current limit have to settle timing and input compatibility.
Can the line handle bulk-packed cable-lead sensors?
Will the line accept bulk-packed cable-lead sensors? E2E-X14MD1S 5M is listed in Bulk with cable leads; match incoming handling and termination to the existing build before committing to sustaining production.
View the Win-Source product page for E2E-X14MD1S 5M.
Key Takeaways for Engineers & Buyers
- Resolve the EOL and Active status conflict before committing E2E-X14MD1S 5M to sustaining builds.
- Check the installed rail against the 30V supply ceiling.
- Test the listed 14mm sensing distance with the installed target and mounting.