15mm inductive sensing, M30 threaded body, 10V ~ 30V supply and -40°C ~ 85°C operating temperature.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM PNP M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
15mm sensing distance puts target position first
15mm is the listed sensing distance, not a guarantee that every metal target will switch at that gap. It's a starting position; target material and geometry still determine whether detection is dependable. The shielded, M30 threaded body needs room that a bracket laid out for a smaller sensor may not have. Inductive sensing also rules out direct detection of nonmetal targets.
250Hz may settle the fast-target question
Fast targets are the weak point. The listed 250Hz response frequency does not establish reliable detection of every passing feature, so compare it with target speed. The electrical and environmental limits are clearer: the 10V ~ 30V supply range sets the permitted supply boundary, and the -40°C ~ 85°C operating-temperature range sets the stated conditions for the machine location. Neither range establishes output load capacity.
Active status supports a new M30 machine installation
New design-in is reasonable. Omron marks E2E-X15B1D30 2M Active in both lifecycle and product status, with no stated conflict; that supports specifying it for a new machine rather than reserving it for sustaining designs. The PNP-NO, 3-wire output must match the machine input, or a correctly positioned target still produces the wrong interface behavior. EU RoHS compliance is listed.
Cable leads are the installation constraint. Specify that termination on the wiring drawing before committing the M30 mounting location; a connectorized harness cannot be attached directly to cable leads. The listed Box packaging does not change the electrical connection. This is a practical choice where the machine already accommodates a threaded, shielded inductive sensor and the cable can be routed from its mounting point.
M30 clearance and 15mm detection still need evidence
M30 clearance needs a dimensional drawing, while detection at 15mm needs target-material correction data. Neither is available here. The cable leads also need a pinout, and the absent output load-current rating leaves the machine input match open.
View the Win-Source product page for E2E-X15B1D30 2M.
Key Takeaways for Engineers & Buyers
- Check the actual target against the listed 15mm sensing distance.
- Match the PNP-NO, 3-wire cable leads to the machine input.
- Check target speed against the listed 250Hz response frequency.