30V supply ceiling, 15mm sensing distance, M30 threaded body, and -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM PNP M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
The M30 mount and 15mm reach decide the design-in
The 15mm reach and M30 body constrain target spacing and mounting clearance. Both have to fit. E2E-X15B230-M1 is a new design-in candidate when they do, but the listed distance isn't a guaranteed switching point for every target. Lifecycle Status and Product Status both say Active, with no stated conflict; EU RoHS compliant status is listed without a directive revision. Neither status changes an installation that cannot accommodate the cylinder or present a suitable target.
The connector pinout is still missing
The connector pinout is missing. PNP-NC, 3-wire establishes output logic, but not which contact carries each connection. Obtain the pinout, connector drawing, and sensing-distance conditions before releasing wiring or target placement.
What must accompany the connector-terminated sensor?
Which mating cordset goes on the order? Box identifies the packaging; Connector identifies the termination. Neither identifies a mating cordset. Define the mating connection for the M30 installation before releasing the purchasing line, or the sensor can be mounted but left unwired. Active status supports a new production choice, not a finished physical interface.
The 30V ceiling does not settle target speed or sealing
30V is the supply ceiling. The listed range starts at 10V, so a rail outside 10V ~ 30V rules out this connection. The listed 250Hz response frequency sets a speed ceiling, not proof that every passing target will be detected. On a moving-metal station, a missed transition reaches the controller as a missed part.
The shielded, M30 threaded inductive body belongs where a metal target can approach within the listed 15mm sensing distance, the mount has room for the cylinder, and the controller accepts PNP-NC, 3-wire output. A smaller mounting opening or an input expecting different output logic rules it out. The -25°C ~ 70°C operating range bounds ambient selection. IP67 and IP69K address ingress protection rather than extending that temperature range; they don't establish the protection of an unspecified mating connection.
View the Win-Source product page for E2E-X15B230-M1.
Key Takeaways for Engineers & Buyers
- Keep the supply within 10V ~ 30V; 30V is the ceiling.
- Check the 15mm sensing distance against the actual target gap.
- Match the PNP-NC, 3-wire output to the controller input.