15mm reach in an M30 body, with a 10V to 30V supply and -25°C to 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM PNP M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new machine build
That leaves new design-in defensible. E2E-X15B3D30 2M is Active across the lifecycle fields, with no status conflict, and is listed as EU RoHS compliant. The machine-fit questions remain.
The 15mm reach cannot fix a rail mismatch
The gap and the rail impose separate limits. The listed 15mm sensing distance does not establish reach for every metal target; set the target position against that figure before fixing the mount. Material-specific reach is not given.
The 10V to 30V supply range bounds the control rail. Outside it, the specified electrical fit is gone. Operating temperature of -25°C to 70°C bounds the installation environment, not conditions inside a hot enclosure. Moving the sensor closer to the target cannot resolve either limit.
M30 mounting and cable leads decide the machine fit
This is a machine-mount sensor. The M30 shielded cylindrical body makes integration a mechanical decision: a bracket cut for another thread won't accept it, and the shielding entry doesn't establish how far the face can sit behind surrounding metal. It is not for PCB mounting.
E2E-X15B3D30 2M has a PNP-NC/NO, 3-wire output. The controller input must accept a sourcing signal and the intended switching sense, or it will read the wrong state. Set cable routing and termination before releasing the BOM; this sensor is described with cable leads, not a connector end.
IP67 and IP69K are listed ingress ratings, not proof that an installed cable junction shares them. The LED can help check state at the machine, but it cannot show what the controller input receives.
250Hz still leaves target timing open
250Hz is the listed response frequency, not a switching-delay figure for the actual target. It cannot close a fast-event timing check on its own. The listing also gives no wiring diagram for the PNP-NC/NO lead assignments or mechanical drawing for face position and mounting clearance. Those details are needed before cutting the bracket or fixing the controller input.
View the Win-Source product page for E2E-X15B3D30 2M.
Key Takeaways for Engineers & Buyers
- Check the 15mm sensing distance against the actual target material and gap.
- Match the 10V to 30V supply range to the controller rail.